INSTALLATION INSTRUCTIONS
Step 4-4. Installing In-line Blowers Duct Detail: ATEX-0.8 8 Round
ATEX-1.2 10 Round
13
Dimensions and Wiring:
Model A C D E Weight
ATEX-0.8 8 12 ½ 15 ½ 7 19 lbs
ATEX-1.2 10 14 15 8 21 lbs
Step 5. Mount Outer Shell to Wall
1. The bottom of the hood should be 30 minimum to 36 maximum above the countertop for efficient operation.
2. This hood is designed to be plugged into a 3-prong Non-GFCI outlet 120Volt, 10 amp. Ensure the outlet is not
obstructed by the duct run prior to installation.
3. If duct cover is being used mount duct cover mounting brackets to top of hood through holes provided. If no duct
cover is being used proceed to Step 5.
4. Anchor hood to wall with appropriate shear strength for weight of hood being installed (hardware not included). A
number of holes are provided on the back of the shell but they do not need to be used. Additional holes can be
drilled if needed to assist in mounting.
5. If duct cover is being used anchor bracket to wall or ceiling (top) and wall (bottom). Do not install duct cover at this
time.
Step 6. Re-install Liner into Outer Shell
Figure A:
Lift Liner into Shell
Carefully re-install liner to
avoid scratches or damage.
Figure B:
Attach Liner to Shell
Re-install with hardware that
mounted liner to shell during
shipment.
Figure C:
Re-install Control Panel
screws (front and back)
attaching panel to ventilation
hood liner.
Step 7. Connect Ducting to Ventilation Hood
Install ducting around starter collar on top or rear of hood and seal according to building code regulations.