TROUBLESHOOTING
PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
The fan is noisy.
1. The blades are loose.
2. There is a cracked blade.
3. The outlet box is not secure.
4. The mounting bracket is not
secure.
1. Check and tighten all screws that hold
the fan blades to the blade arms and the
motor.
2. Replace the cracked blade.
3. Ensure the ceiling outlet box is secured
to the building structure.
4. Ensure the mounting bracket is secured
to the outlet box and that the screws are
tight.
Remote control
does not work.
1. Power surge may have
cleared memory and remote
needs to be re-synced to the
reciever.
2. Battery in remote control
needs to be replaced.
3. Interface from another
remote.
1. After installation is complete, switch the
power off and back on again. Within
30 seconds, remove the battery from
remove pack (Q). Press and hold the
“LEARN” button, located in the battery
compartment, for 5 seconds. Fan
will turn on at low speed and light (if
installed)off.Thisconrmsthatthe
SMART SYNC is active.
2. Insert new 12V battery in battery
compartment of the remote control (see
page 13).
3. If there are several fans in close
proximity, turn power off to other fans
and re-sync the remote (see Corrective
Action 1 above).