Connecting to external ducting
o Connect the coupling to the top of the cooker hood, using two of
the smaller screws provided.
o Connect a 150 mm ducting hose to a discharge outlet that is
suitable for cooking vapours. If you need to fit a 125 mm ducting
hose, then a reducer is supplied with the appliance to allow you
to do this.
o The discharge outlet should have a cross section of at least 150
cm² (please note that the ducting hose is not supplied with the
appliance but one can be obtained from the Baumatic Spares
Department).
o The maximum distance between the coupling and your discharge
outlet should be 3 metres, with one 90 degree bend. For each
additional 90 degree bend, the maximum distance is reduced by
a further metre.
o Before fixing the cooker hood into the kitchen unit, you should
connect the other end of the ducting hose to the coupling in the
top of the cooker hood.
Completing the installation
If you are setting the appliance to recirculation mode, then you should
now fit the two carbon filters. See the “Fitting the carbon filter”
section.
The electrical connection must correspond to the electrical requirement
noted on the rating plate, which is placed inside the cooker hood. The
appliance should now be connected to the electrical supply.
Refit the metal filter and then switch on the mains supply
to the appliance. Check that the appliance is operating