INSTALLATION
Safety
16 | CNS S | CNS U www.stiebel-eltron.com
INSTALLATION
7. Safety
Only a qualified contractor should carry out installation, commis-
sioning, maintenance and repair of the appliance.
7.1 General safety instructions
We guarantee trouble-free function and operational reliability only
if original accessories and spare parts intended for the appliance
are used.
WARNING Electrocution
Install the appliance in such a way that control equipment
cannot be touched by a person in the bath or shower.
!
Material losses
- Only fit the wall mounted appliance to a vertical wall
that is temperature-resistant to at least 85 °C.
- Maintain the minimum clearances to adjacent object
surfaces.
- Never install the appliance directly below a wall
socket.
- Ensure that the power cable is not in contact with
any appliance components.
7.2 Instructions, standards and regulations
Note
Observe all applicable national and regional regulations
and instructions.
8. Appliance description
8.1 Standard delivery
The following are delivered with the appliance:
- Wall mounting bracket (hooked into the appliance)
9. Installation
9.1 Minimum clearances
20
≥100 ≥500≥100
≥100
≥150
D0000019283
9.2 Installing the wall mounting bracket
Note
You can use the wall mounting bracket as a template for
wall mounting; this ensures the required floor clearance.
aaa
26_07_31_0124
1
3
2
4
Unhook the wall mounting bracket.
Place the centred wall mounting bracket level on the ground
and mark holes 1 and 2.
Lift up the wall mounting bracket so that its lower holes
match up with the markings you have just made on the in-
stallation wall.
Mark holes 3 and 4 on the installation wall.
Drill holes at all four markings. Secure the wall mounting
bracket with suitable materials (screws, rawl plugs) depend-
ing on the type of wall. With the vertical slots, you can com-
pensate for an offset fixing hole.