Connecting the powerConnecting the power
Connecting the power
Step 2. Accessing the power cord connection
Loosen and then remove the rear access cover screw with a screwdriver. Remove
the rear access cover by pull right and then out. The terminal block will then be
accessible.
Terminal block
Access cover
Specied rating of power-supply-cord kit and circuit protection
Range rating, watts
Specied rating
of power-supply-
cord kit and
circuit protection,
Amps
Diameter (inches) of range
connection opening
120/240 volts
3-wire
120/208 volts
3-wire
Power cord Conduit
8750-16500 7801-12500 40 or 50 A 1
3
8" 1
1
8"
This appliance must be supplied with the proper voltage at the proper frequency
and must be connected to a dedicated, properly grounded branch circuit protected
by a 40 amp or larger circuit breaker.
NOTE
For power cord installations, go to Step 3. For conduit installations, go to Step 4 on
page 11.