Loading ...
Loading ...
Loading ...
English 11
Connecting the power
Step 4. Installing the conduit
Remove the conduit connection plate and rotate it as shown below.
The conduit hole (1
1
8") must be used.
1
1
8"
1
1
8"1
3
8"
1
3
8"
1. Prepare the conduit cord as shown in Figure 1.
2. Install the conduit cord as shown in Figure 2.
Knockout surface
Conduit connection plate
Strain relief
Ring
Body
Figure 1
3 wire 4 wire
Figure 2
1" 1"
3
8"
3
8"
3
1
2" 3
1
2"
For conduit installations, insert the strain relief (not included) into the conduit
hole (1
1
8"). Then thread the conduit cord through the body of the strain relief and
fasten the ring. Reinstall the bracket.
Installing a 3-wire conduit
Aluminum building wire may be used but it must be rated for the correct
amperage and voltage. Connect the wires as described below.
The wire you use, the location and enclosure of splices, etc., must conform to
good wiring practices and local codes.
1. Loosen the 3 lower terminal screws from the terminal block.
2. Insert the center bare wire (white/neutral) tip through the bottom center
terminal block opening. On certain models, the wire will need to be inserted
through the ground strap opening and then into the bottom center block
opening.
3. Insert the two side bare wire tips into the lower left and the lower right
terminal block openings.
4. Tighten the screws until the wire is rmly secured (35 to 50 inch-lbs.). Do not
over-tighten the screws since it could damage the wires.
5. Go to Step 5 on page 13 to continue with the installation.
Ground strap
Live 2
Wire tips
Neutral terminal
Live 1
Black
Black
White
White
Red
Red
Install_NE63T8911_AA_DG68-01257A-00_EN.indd 11 2020-03-26  6:27:51