07-02284A 5 LBG Distribution
Maintenance
Before each use
Inspect the electrical cord for damage. Look for fraying,
cuts, etc. Do not use the unit if you find any damage.
Inspect and vacuum filter as needed. Keep a clean filter in
the unit at all times to protect internal components from
dust and other particulate build-up. The LGR 130 is
equipped with a 3M™ High Air-Flow filter. The HAF filter
may be vacuumed clean and reused up to three times. Do
not rinse or wash the HAF filter, as it will reduce the
effectiveness of the electrostatic material. Replace only
with a new 3M HAF Filter (LBG Distribution part no. F372)
CAUTION: Dust can cause the unit to overheat and shut
down. Do not operate when excessive dust or airborne
particles are present, such as during sanding or spray-
painting. Inspect and clean air filter elements and coils
frequently.
IMPORTANT: Replace the HAF filter whenever 1) it has
been vacuumed clean 3 times or 2) it has been used on
a mold remediation job or otherwise exposed to
potentially dangerous contaminants.
Monthly
Check coils. Dirty coils can cause the unit to overheat. Clean
when visibly dirty. See Fig. C.
1. Unplug unit
2. Remove housing, locate coils and allow coils to dry if
wet.
3. Vacuum coils surfaces until clean, being careful not to
let the nozzle touch the fins, as that may cause damage by
bending them.
Check catch basin tray, and wipe clean with a rage when dirt
and debris are present.
Check drain hose.
1. Look for obstructions. Disconnect and clear any debris
present.
2. Reattach gravity drain hose.
Inspect filter cover
1. Remove the filter cover (this can be done without removing the housing).
2. Vacuum off any visible dirt, or wash with mild soap and water.
3. Allow to dry thoroughly before replacing.
Annually
Have the pump system inspected by a qualified service center. If you wish to inspect the pump yourself, remove the four
bolts located at the bottom of the unit (Fig. B). Use a ⅜-in. nut driver or socket.
TRANSPORT AND STORAGE
NOTICE: Handle the unit carefully. Do not drop, throw, or place the unit where it could fall. Rough treatment can
damage this equipment and may create a hazardous condition or void warranty.
FIG. B: PUMP ACCESS PANEL
To access the
pump, remove
the four bolts
(circled) on the
lower panel.