S-DD2-L FLUSH TOP
INSTALLATION GUIDE
WARNING
After having replaced the filters, reinstall
the front stainless steel panel, otherwise
the Downdraft is not enabled to function.
Water splashing against the enclosure from any
direction shall have no harmful effect, utilizing either:
a) an oscillating fixture, or b) A spray nozzle with no
shield.
Test a) is conducted for 10 minutes. Test b) is
conducted (without shield) for 5 minutes minimum.
Oscillating tube: Test duration: 10 minutes, or spray
nozzle (same as IPX3 spray nozzle with shield
removed).
(Fig. 8)
ELECTRICAL CONNECTION
CAUTION
DANGER
NOTE
While installing the appliance and carrying
maintenance operation, make sure it is disconnected
from the electrical network or the fuses are cut out or
removed.
Check that:
Power is connected.
Feeder lines (mains) are in good conditions.
The cables diameter complies with installation
regulations.
This appliance is fitted with an H05 VVF 3 conductor,
0.75 mm2 (neutral, phase, and ground) power cord.
This can be connected up to a 220 - 240 V
monophase electrical network through a CEI 60083
approved power socket (10AMP power socket),
which must remain accessible after installation, in
compliance with installation regulations. We decline
any responsibility in case of accidents caused by
a lack of ground connection or incorrect ground
connection. The appliance must be fed through a
differential protection device (RCD), with a nominal
residual current not exceeding 30mA. If the power
cord is damaged, call the after-sales service to avoid
any risk.
If the appliance has no plug or if the plug is not
easily accessible, then a device needs to be fitted to
disconnect off from the electric network; this device
must have an opening distance between contacts on
all poles of at least 3 mm.
This appliance complies with the European
Directives 2006/95/EC (Low Voltage
Directive) and 2004/108/EC (Electromagnetic
Compatibility).
If the rangehood presents any anomaly,
disconnect the appliance or remove the
fuse corresponding to the appliance
power disconnecting line.
WARNING
The downdraft connection to the electrical
network must be carried out only by
professional and qualified technicians.
The downdraft must be connected to a properly
installed and suitable electrical network.
The electrical system must comply with VDE0100
standard.
NOTE