INSTALLATION - GAS CONNECTION
REGULATION OF THE INJECTORS :
 INJECTORS OF THE HOB : To reach the injectors one must :
- Remove the pan supports, and the burner caps,
- Unscrew the injectors, using the special key supplied with the appliance,
- Replace with the new injector according to gas type installation.
The numbers marked on the injectors are shown on the table page 35.
INJECTOR OF THE OVEN : The flat burner is connected by its neck to the injector
support. At the front, it leans on a support which has two grooves, a central screw fixes it
to the oven bottom.
To remove this burner one must :
- take off the bottom plate of the oven,
- take off the central screw, lift gently the front part of the burner to remove it from the
two grooves.
- pull the burner forwards to remove it from the injector support,
- take off the injector and replace it with the new component according to the type of gas
available.
TO CORRECT THE FLAME :
1. Regulation of the air flow.
When necessary (see the table page 35) this regulation is very important because it obtains
proper combustion and the best efficiency of the burner.
The air flow regulator is correctly positioned when
the "x" level shown on the table is complied with.
2. Accessibility to the air flow regulator.
To reach the air flow regulator of the hob, remove the pan supports, the burner caps and
burner supports. The air flow regulator is under the burner head assembly. This is fixed
with a screw.
3. Regulation of the air flow (for the oven).
To reach the air flow regulators of the oven, follow the same instructions which apply to
the injectors. The regulations are stated in the table on page 35.