GETTING TO KNOW YOUR HUMIDIFIER
How It Works
Water is released into the Reservoir when the Float Paddle engages the Plunger at the bottom
of the Water Tank. A Nebulizer vibrates at ultrasonic frequency, breaking the water into a fine
mist. The mist is quietly propelled by a fan up a vertical Mist Chamber to the Mist Outlet where
the cool, visible mist enters the room. This humidifier will shut off when the water level is low
or when the tank is removed from the base.
IMPORTANT SAFETY
INSTRUCTIONS
READ AND SAVE THESE SAFETY
INSTRUCTIONS BEFORE USING
THIS HUMIDIFIER
When using electrical appliances, basic
precautions should always be followed to
reduce the risk of fire, electrical shock and
injury to people, including the following:
1. The humidifier should always be placed on a
firm, flat, waterproof surface at least four feet
(1.2m) away from bedside, 12 inches (30 cm)
from the wall and out of reach of patients,
children and pets. Be sure the humidifier is in
a stable position and the power cord is away
from heated surfaces and out of the way to
prevent the humidifier from being tipped over.
2. The humidifier should not be left unattended
in a closed room since air could become
saturated and leave condensation in front
of unit, on walls and furniture. Leave room
door partly open. Do not aim Mist Outlet
directly at children, walls or furniture.
3. Before using the humidifier, extend the cord
and inspect for any signs of damage. Do not
use the unit if the cord has been damaged.
Do not operate with power cord coiled or with
twist tie in place.
4. The humidifier has a polarized plug (one blade
is wider than the other) as a safety feature.
This plug will fit into a polarized outlet only
one way. If the plug does not fit fully into the
outlet, reverse the plug. If it still does not fit,
contact a qualified electrician. Do not attempt
to defeat this safety feature.
5.
CAUTION: To avoid fire or shock
hazard, plug the humidifier directly into a
120V AC electrical outlet. To avoid risk of
fire, shock or personal injury do not use an
extension cord or power strip.
6. The humidifier should always be
unplugged and emptied when not in
operation or while being cleaned. Shut
off and unplug humidifier before moving.
Do not move or tilt humidifier while it is
in operation. Plug and unplug unit with
dry hands. Never pull by cord.
7. Do not operate the humidifier without
water. Turn off and unplug unit when
tank is empty.
8. Humidifier requires regular cleaning. Refer
to and follow cleaning instructions.
9. Do not operate outdoors; this humidifier
is intended for indoor residential use only.
10. Do not cover or insert objects into any
openings on the unit.
11. Do not block intake or output vents.
12. Do not attempt to repair or adjust any
electrical or mechanical functions on
this humidifier. Doing so will void your
warranty.
13. Do not place in direct sunlight, high
temperature areas or near computers or
sensitive electronic equipment.
14. Do not touch the nebulizer while the unit is
plugged in, as burns could result.
15. Do not add any medications (e.g. liquid
inhalant, Vicks VapoSteam
®
or oils)
into Mist Outlet, Water Reservoir or
Water Tank.
SAVE THESE INSTRUCTIONS
13 Demineralization
Cartridge
(included in some models)
14 Plunger
15 Tank Gasket
16 Float Paddle
17 Air Outlet
18 Water Reservoir
19 Nebulizer
1 Mist Outlet
2 Outlet Gasket
3 Outlet Cover
4 Tank Handle
5 Tank Opening
6 Tank Cover
7 Water Tank
8 Auto Shut-Off Float
9 Housing
10 Base
11 Power Knob
12 Mist Chamber
Unpack the Humidifier
Keep this instruction manual for reference.
1. Remove packaging
materials. Locate
Float Paddle (A)
and set aside.
This is required for
operation.
2. Locate the Demineralization Cartridge (B) (included with some models) and set aside.
This is optional for operation.
3. Remove twist tie and extend power cord. Place on a firm, level, water resistant surface
a minimum of 12 inches (30 cm) from walls.
SETTING UP YOUR HUMIDIFIER
Components
MAX
MAX
10
1
2
3
4
9
7
6
5
14
13
8
17
12
19
18
16
15
11
Step 2 Step 1 Step 3