Installation
105
EN
5.6 Electrical connection
General information
Check the grid characteristics against the
data indicated on the plate.
The identification plate bearing the
technical data, serial number and brand
name is visibly positioned on the appliance.
Do not remove this plate for any reason.
Perform the ground connection using a wire
that is 20 mm longer than the other wires.
The appliance can work in the following
modes:
65 - 75 cm models:
220-240 V 1N~
3 x 1.5 mm² three-core cable.
90 cm models:
220-240 V / 380-415 V 2N~
6 x 1.5 mm² six-core cable.
3 x 6 mm²
three-core cable.
Power voltage
Danger of electrocution
• Have the electrical connection
performed by authorised technical
personnel.
• Use personal protective equipment.
• The appliance must be connected to
earth in compliance with electrical
system safety standards.
• Disconnect the mains power supply.
• Do not pull the cable to unplug the
appliance.
• Use cables withstanding a temperature
of at least 90°C.
• The tightening torque of the screws of
the terminal supply wires must be 1.5 -
2 Nm.
• If it is necessary to replace the power
cable, this must only be performed by
a qualified technician.
The values indicated refer to the
cross-section of the internal
conductor.