Loading ...
Loading ...
Loading ...
en Positioning and connecting
18
Alignment
Level the appliance using a spirit level.
Incorrect levelling may result in intense
noise, vibrations and "wandering".
1. Loosen the lock nuts using a
wrench, by turning it in a clockwise
direction.
2. Check the alignment of the
appliance with a spirit level, and
adjust it if necessary. Change the
height by turning the appliance feet.
All four appliance feet must stand
firmly on the ground.
3. Tighten the lock nut against the
housing.
In doing so, hold the foot tight and
do not adjust its height.
The lock nuts on all four appliance
feet must be screwed tightly against
the housing.
Electrical connection
:Warning
Risk of death!
There is a risk of electric shock if you
touch live components.
Never touch or hold the mains plug
with wet hands.
Only pull out the mains cable by the
plug and never by the cable, as this
could damage it.
Observe the following information and
ensure that:
Notes
The mains voltage and voltage
indicated on the appliance (rating
plate) are the same.
The connected load and fuse
required are specified on the rating
plate.
The appliance is only connected to
an alternating current via a properly
installed earthed socket.
The mains plug fits the socket.
The earthing system is properly
installed.
The mains cable is only replaced by
a qualified electrician (if this is
necessary). Replacement mains
cables are available from the after-
sales service.
No multiple plugs/couplings or
extension cables are used.
If an earth-leakage circuit breaker is
used, only a type which displays this
symbol is used: z.
Only this symbol guarantees
compliance with the currently
applicable regulations.
The mains plug can be accessed at
all times.
The mains cable is not bent,
squashed, modified, cut through, or
in contact with heat sources.
Loading ...
Loading ...
Loading ...