User Manual - Page 17

For DLHF0817G. Series: 2.0
Also, The document are for others Crossover models: DLHF0817GMI, DLHS0817GMI, DLHS0817G

Loading ...
Loading ...
Loading ...
Service Mode
4:4
044 Time for ATS for High heat(range=1-90, default=40).
045 Time for ATS for Medium heat(range=1-90, default=40).
046 Time for ATS for Low heat(range=1-90, default=40).
047 Time for ATS for No heat(range=1-90, default=40).
048 Time for additional coin or push for High heat (range = 0-90, default = 6).
049 Time for additional coin or push for Medium heat (range = 0-90, default = 6).
050 Time for additional coin or push for Low heat (range = 0-90, default = 6).
051 Time for additional coin or push for No heat (range = 0-90, default = 6).
052 Max drying time - High (range 1-90, default = 90).
053 Max drying time - Medium (range 1-90, default = 90).
054 Max drying time - Low (range 1-90, default = 90).
055 Max drying time – No Heat (range 1-90, default = 90).
Temperature and Cooling Settings:
060 Set temperature for High (range 0-80C,default=65°C/150°F).
061 Set temperature for Medium (range 0-80C,default=57°C/135°F).
062 Set temperature for Low (range 0-80C, default=49°C/120°F).
063 Set temperature for No Heat (range 0-80C, default=0°C/32°F).
064 Cool down time for High (minutes, range 01-10, default=01).
065 Cool down time for Medium (minutes, range 01-10, default=01).
066 Cool down time for Low (minutes, range 01-10, default=01 )
067 Cool down time for No Heat (minutes, range 01-10, default=01).
068 Cool down temperature for High (range 27-60°C, 80-140°F, default =49°C/120°F).
069 Cool down temperature for Medium (range 27-60°C, 80-140°F, default =49°C/120°F).
070 Cool down temperature for Low Heat (range 27-60°C, 80-140°F, default =49°C/120°F).
071 Cool down temperature for No Heat (range 27-60°C, 80-140°F, default =49°C/120°F).
During cool down time, display shows c 01 > c 00 (machine stops at 00).
During remaining wait time for cool down temperature, display shall show “c --”.
Real Time Clock and Promotion Settings:
072 RTC set-up:24 hr format,072”>yyyy>D>mm.dd>hh.mm>072. Where: yyyy=year, D=day
of week (“1”=Sunday), mm.dd=month & date, hh.mm=24 hr time.
Note: During set up, the RTC shall be stopped. When “Start” is pressed to save new hh.mm
value, the seconds digits of the RTC shall be set to “00” without affecting the hours and
minutes values, and the RTC shall be re-started.
Loading ...