Service Mode
4:3
Operating Test Registers:
Note: Activation of test 020-023 clears previous value stored in register 028.
*020 Run, Heat to 65°C (display shows outlet temperature blinking, while operating).
*021 Run, Heat to 57°C (display shows outlet temperature blinking, while operating).
*022 Run, Heat to 49°C (display shows outlet temperature blinking, while operating).
*023 Motor ON, Runtime 60 minutes, No heating (display shows outlet temperature blinking,
while operating).
NOTE: When registers 020-023 are active, press and hold “High “temperature pushbutton to
show actual INLET air temperature. Release High temperature button to return to display of actual
OUTLET air temperature. When outlet air temperature reaches value specied for register 020-022,
cool-down shall be executed with outlet temperature displayed, just as if a regular drying program
were running. When cool-down completes, machine stops.
*024 Buzzer test
*025 Display test
*026 Coin meter test. (Each dropped coin adds 1 to displayed total - registers 005 and 006
are not incremented).
*027 Displays current time: “027”>yyyy>mm.dd>hh.mm>”027. (Read only).
*028 Recorded rate of inlet air temperature rise (degrees per minute) during most recent test
(Reserved for future use)
Payment Conguration Registers:
030 Coin Mode/Token Mode. (range=0-1, default=”0” coin mode).
When set to “token mode” the decimal point in the display will be suppressed when
programming prices and when displaying cycle price information in standby mode.
031 Coin value 1 (range=”0.00”-”9.99, default=”0.25”, omit decimal if register 030=”1”).
032 Coin value 2 (range=”0.00”-”9.99, default=”1.00”, omit decimal if register 030=”1”).
033 Display price or “FILL” / price as standby (range “0”-”1, default=”0” (price), “1”=”FILL” /
price alternating at 0.5 Hz).
034 Standby value blinks. (range”0”-”1, default=”1” (blinking)).
035 Auto start paid. (range”0”-”1, default=”0” (auto start paid disabled).
When Auto Start Paid is enabled, if the loading door is closed when drying time is added,
the machine shall start automatically.
Price and Time Settings:
040 Amount to start (ATS) for High heat program (range=0.00-9.99, default= 0.00).
041 Amount to start for Medium heat program (range=0.00-9.99, default=0.00).
042 Amount to start for Low heat program (range=0.00-9.99, default=0.00).
043 Amount to start for No heat program (range=0.00-9.99, default=0.00).
▼ means registers following (marked with ▲) will be automatically set to the same value entered