Karcher 1.367-163.0 HD 7.9/72-4 Cage Ec

User Manual - Page 12

For 1.367-163.0.

PDF File Manual, 44 pages, Read Online | Download pdf file

1.367-163.0 photo
Loading ...
Loading ...
Loading ...
– 10
WARNING
Repair work and work on the electrical
components may only be performed by an
authorised customer service.
Only Listed fuses with the ratings specified
on the transformer are allowed as replace-
ment fuses.
1 Fuse 0.25 A, T, 6.3x32 mm
2 Fuse 2A, T, 5x20mm
The indicator lamps display the operating
states (green) and interruptions (red).
Reset:
Set the appliance switch to "0".
Wait for a while.
Set the appliance switch to "I".
Continuous green:
The appliance is now ready for opera-
tion.
Continuous red light:
Water shortage
No power
Check whether the voltage indicated on
the type plate corresponds to the volt-
age of the socket.
Check the mains connection cable for
damages.
The water shortage safeguard was trig-
gered due to low water inlet pressure.
The indicator lamp "lack of water" will il-
luminate.
Check water inlet pressure, minimum
value see "Specifications".
Turn the device switch to "0" and turn
on again to restart the system.
Motor overloaded/overheated or the
motor circuit breaker has tripped.
Switch off appliance and let it cool
down. Remove the cause of the prob-
lem. Turn on the appliance again.
Wrong nozzle
Check nozzle for correct size (see tech-
nical specifications).
Flushed the nozzle.
Clean/ replace nozzle.
Filter is dirty.
Clean filter at the water connection.
Unscrew the filter casing, remove the
filter, clean it and replace it.
Air within the system
Appliance ventilation:
Unscrew the nozzle. Switch on the ap-
pliance and let it run until the water ex-
iting from the spray pipe is bubble-free.
Switch off the appliance and fit the noz-
zle again.
Pipe inlets to pump are leaky or blocked
Check all supply lines to the pump for
leaks or blockages.
3 drops per minute are permitted and
can come out from the lower side of the
appliance. Call Customer Service if
there is heavy leakage.
Check all supply lines to the high-pres-
sure pump for leaks or blockages.
Appliance ventilation:
Unscrew the nozzle. Switch on the ap-
pliance and let it run until the water ex-
iting from the spray pipe is bubble-free.
Switch off the appliance and fit the noz-
zle again.
Fuses
Indicator lamp
Operating status display
Fault indication
Appliance is not running
Device is not building up pressure
High pressure side is leaky
High pressure pump is vibrating
12 EN
Loading ...
Loading ...
Loading ...