37
Troubleshooting
SYMPTOM CAUSE POSSIBLE SOLUTION
Controller not ON. Power not ON.
Press the power button on the controller.
Not plugged in.
Plug controller into power supply and power supply into wall
outlet.
Circuit breaker tripped.
Check wall outlet circuit breaker and reset if tripped.
Controller malfunction.
Call Masterbuilt Customer Service.
Fan not ON. Temperature in cabinet has reached
the set temperature.
Once the set temperature is reached the fan will turn off. Once
the temperature falls below the set temperature the fan will
restart. The fan will continue adjusting itself automatically to
maintain the set temperature.
Hopper lid open.
For safety, the hopper is equipped with shut-off switches to
prevent the fan from stoking the fire when these doors are
open. Closing the doors will engage the switches, allowing the
fan to continue normal operation.
Ash door open.
Fan disconnected from controller.
Check that connection is fully seated.
Fan disconnected from wiring harness.
Hopper lid switch disconnected.
Ash door switch disconnected.
Err 3
See below.
Controller temperature
inaccurate.
Temperature probe not fully plugged in.
Check that connection is fully seated.
Temperature probe is dirty.
Carefully clean temperature probe.
Slow heating. Shutdown slides not removed.
Remove shutdown slides.
Low charcoal.
Refill hopper with charcoal.
Grill lid open.
Close grill lid.
Fan not on.
See “Fan not ON.”
Excessive smoke leaking
from hopper.
Loose seal at hopper lid.
Tighten hopper lid latch.
Loose seal at ash door.
Tighten ash door latch.
Loose seal between top and middle
hopper sections.
After hopper is cold, remove heat shield and tighten screws
between top and middle hopper sections.
Err 1 Temperature probe not fully plugged in.
1. Check that connection is fully seated.
2. Unplug controller from power supply, wait 10 seconds and
reconnect.
Err 2 Meat probe malfunction.
Call Masterbuilt Customer Service.
Err 3 Grill overheated.
1. Turn off grill.
2. Check for cause of overheat.
• Grease fire.
• Fan malfunction.
3. Restart grill.
Err 4 Charcoal failed to ignite.
1. Ensure shutdown slides are removed.
2. Ensure hopper lid and ash door are fully closed.
3. Ensure charcoal is not empty.
4. Ensure old ash from previous use has not blocked up the ash
grate. Shake grate to allow all the old charcoal to fall thru it.
5. Restart grill.
Err 5 Meat Probe Temp above 300°F.
1. Using protective gloves, remove meat probe from grill.
2. Unplug from controller.
3. Allow meat probe to cool.
Poor Wifi connection Weak signal.
1. Angle the antenna on back of controller to point at the ground