Cassette Set up for Safe Handling (E12) Labels
Use Cassette’s to select different label sizes. After a Cassette preset function key has been assigned, follow the
steps below to program the label spec and label format for each cassette.
Before the Safe Handling (E12) labels can be used, the scale needs to be set up for the new label size.
1. Load the labels. Refer to Loading/Unloading Labels.
2. Make sure nothing is on the weigh platter.
3. Select the desired Cassette preset function key.
NOTE: Scale will beep two times to indicate Cassette preset function key has been selected.
4. Key in 6000 and press the Mode key. Display will show: B00 SETUP
5. Enter 951753 and press the PLU key.
6. Key in 11 and press the Enter key. Display will show: B11 CASSETTE
7. Press the Enter key. Display will show: B11-01 CAST No. “01”
NOTE: Up to seven cassettes can be programed. Each cassette contains the label spec and label
format for a label.
8. Press the down arrow key on the Scale Set-Up Keysheet three times. Display will show: B11-04 FMT No.
“001”
9. Key in format number “002” and press the Enter key. Display will show: B11-04 FMT No. 002
10. Press the End key. Display will show: B11 CASSETTE
11. Press the down arrow key on the Scale Set-Up Keysheet one time. The display will show: B12 LABEL SPEC
12. Press the Enter key. Display will show: B12-01 LABEL No. “02”
13. Use the down arrow key to select B12-12 LABEL GAP 2.0 mm
NOTE:Labelgapisthepitchbetweenlabels.Dependingonthelabel,asmalladjustmentmayneedto
be made.
14. Press the down arrow key on the Scale Set-Up Keysheet one time. Display will show: B12-13 SENS DIST.
“71.0mm”
15. Key in 710 (do NOT enter decimal point) and press the Enter key.
16. Press the End key. Display will show: B12 LABEL SPEC
17. Press the down arrow key one time. The display will show: B13 LABEL FORMAT
18. Press the Enter key. Display will show: B13-01 <BASIC>
19. Press the down arrow key on the Scale Set-Up Keysheet two times. Display will show: B13-01-02 WIDTH
“560”
20. Key in 560 (do NOT enter decimal point) and press Enter key.
21. Press the Enter key again. Display will show: B13-01-03 HEIGHT “440”
22. Key in 590 (do NOT enter decimal point) and press the Enter key.
23. Press the Mode key three times to return to normal operation.
NOTE: It may be necessary to print two or three labels in order for the alignment to appear correct on
the label.