Setting Up PLUs
1. Make sure the scale is plugged in, turned on and there is nothing on the platter.
2. Key in 9000 and press the Mode key. Display will show: P00 PROGRAM
3. Press the Enter key. Display will show: P01 PLU
4. Key in 111111 and press the PLU key.
5. Press the Enter key. Display will show: P01-00 PLU >No<
6. Key in the PLU number (5 digit maximum) and press the PLU key. Display will show: 13001-0000 ENT OR
CLR.
NOTE: Press the Enter key to accept the PLU number or the CLR key to cancel. CLR will return you to
the PLU number entry screen and Enter will move forward to the top of the PLU entry menu.
7. Display will show: P01-01 <SALE1>
8. Press the Edit key. See Figure 10-1. Display will show: INP 0001-0000 00
9. Use the Scale Set-Up Keysheet to key in the PLU name (24 character
maximum per line, 2 line maximum, e.g. GROUND BEEF, BANANAS). See
Figure 10-2.
10. Enter the rst line of data. If you only want one line of data, then press the
Enter key. If you want a second line of data, press the New Line key. Enter
the second line of data, and press the Enter key to complete. See Figure
10-3. Display will show: P01-01 <SALE1>
11. Press the Enter key. Display will show: P01-01-01 SALES 0
12. Key in 0 if the PLU is a weighing price item. Key in 1 if the PLU is a xed
price item.
NOTE:Forweighingpriceitems,proceedtostep13.Forxedprice
items, proceed to step 18.
13. Press the Enter key. Display will show: P01-01-04 PRICE 0.00
14. Key in the unit price (5 digit maximum do NOT include decimal) and press
the Enter key.
15. Press the Enter key again. Display will show: P01-01-10 TARE 0.000
16. Key in the tare weight (4 digit maximum/2 digit minimum - tare weight is a
three place decimal that must end in 0 or 5) or 0 if none and press the Enter
key two times. Display will show: P01-01-12 P TARE 0.0
NOTE: For a detailed explanation of tares, refer to the Tare Weight
section.
17. Key in the tare percentage (3 digit maximum) or 0 if none and press the
Enter key.
NOTE: For weighing price items, proceed to step 26.
18. Press the Enter key. Display will show: P01-01-04 PRICE 0.00
19. Key in the unit price (5 digit maximum) and press the Enter key.
20. Press the Enter key again. Display will show: P01-01-06 QTY 0
21. Key in quantity. Press the Enter key.
22. Press the Enter key again. Display will show: P01-01-07 UNIT TYPE 0
23. Key in unit type. Press the Enter key.
24. Press the Enter key again. Display will show: P01-01-09 FIX WGT 0
25. Key in xed weight. Press the Enter key.