104 Servicing Your Honda
Suspension
12. Pour the recommended fork oil (page 91) into
the inner chamber (10).
Left Fork Inner Chamber Oil Capacity:
Approximately 0.03 US oz (1.0 cm
3
) of fork oil
remains after draining.
This amount must be noted when filling to the
standard oil capacity.
13. Remove the O-rings (11) from the fork cap (6).
14. Apply recommended fork oil to new O-rings
and install them to the fork cap.
15. Install the fork cap.
16. Press the fork cap (6) and install the stopper
ring (7) securely.
17. Pull up the fork cap.
18. Apply air pressure to the inner chamber
through the inner chamber air valve (3) and
check that there is no air leakage. Install the
valve cap.
Air fork pump 07AMJ-KRNA100
(USA only)
Air fork pump adapter 07AMJ-KRNA110
(USA only)
Inner Chamber Air Pressure:
When applying air pressure to the inner chamber,
the fork will be extended.
19. Apply air pressure to the outer chamber through
the outer chamber air valve (4) and check that
there is no air leakage. Install the valve cap.
Air fork pump 07AMJ-KRNA100
(USA only)
Air fork pump adapter 07AMJ-KRNA110
(USA only)
Outer Chamber Air Pressure:
When applying air pressure to the outer chamber,
the fork will be extended.
20. Apply air pressure to the balance chamber
through the balance chamber air valve (5) and
check that there is no air leakage.
Air fork pump 07AMJ-KRNA100
(USA only)
Air fork pump adapter 07AMJ-KRNA110
(USA only)
Balance Chamber Air Pressure:
When applying air pressure to the balance
chamber, the fork will be shortened.
(10) inner chamber
Standard oil
capacity
3.0 US oz (90 cm
3
)
(6) fork cap (11) O-rings
(10)
(11)
(6)
(6) fork cap (7) stopper ring
Standard 156 psi (1,075 kPa, 11.0 kgf/cm
2
)
Maximum 170 psi (1,175 kPa, 12.0 kgf/cm
2
)
Minimum 141 psi (975 kPa, 9.9 kgf/cm
2
)
(6) (6)
(7)
Standard 12 psi (80 kPa, 0.8 kgf/cm
2
)
Maximum 15 psi (100 kPa, 1.0 kgf/cm
2
)
Minimum 9 psi (60 kPa, 0.6 kgf/cm
2
)
Standard 156 psi (1,075 kPa, 11.0 kgf/cm
2
)
Maximum 189 psi (1,300 kPa, 13.3 kgf/cm
2
)
Minimum 131 psi (900 kPa, 9.2 kgf/cm
2
)
(3) inner chamber air valve
(4) outer chamber air valve
(5) balance chamber air valve
(3) (4)
(5)