CART MODELS: Please follow the instructions supplied with the unit in order to mount and connect all
required piping that comes with the unit.
WARNING:
To prevent harm and ensure proper operation of your Side Burner, it is imperative that the burners are
properly installed with respect to the gas orifices. Be certain that the exterior cap and well as internal cap
is inserted completely into the burner’s venture funnel and that the burner rests firmly on its supports.
The burner should not rock side-to-side nor top-to-bottom if properly installed. If excessive burner
movement is present, reseat burner or contact your authorized service provider.
ELECTRICAL REQUIREMENTS:
The AXESB-2 Side Burner is equipped with a high output electrical ignition system and accent lights on
the front panel of the unit.
The electrical system is designed to be operated at:
115VAC - 50 / 60 Hz.
The unit should be kept plugged into the receptacle (located
under the counter and away from the elements) except when it
is being disconnected for maintenance or troubleshooting (see
page 15).
We recommend using a GFCI Receptacle to maintain proper
grounding and safety at all times.
GAS CONNECTION—LIQUID PROPANE (LP)
NEVER CONNECT THE SIDE BURNER TO AN UNREGULATED GAS SUPPLY.
Before proceeding, ensure the unit is fitted for LP gas. Connecting to an improper gas type will result in
poor performance and increased risk of damage or injury. Total gas consumption (per hour) with all
burners set on “HI” is a follows:
 AXESB-2 40,000 BTUH
The installation of this appliance must conform with local codes or, in the absence of local codes, to the
national fuel gas code, ANSI Z223.1a-1988. Installation in Canada must be in accordance with the
Standard CAN/ CGA-B149.1 Natural Gas Installation or CAN/CGA-B149.2, Propane Installation Code.
Manifold pressure with LP Operating: 10.0” W.C. Non-operating: 11.2” W.C.
L.P. TANK REQUIREMENTS:
Use only a standard 20 Lb. (5 Gal.) propane gas cylinder (18-1/4” H x 12-1/4” Ø). The tank must be
installed in the upright position. Do not use a dented or rusty LP tank as it may be hazardous and should
be checked by your LP supplier. Never use a cylinder with a damaged valve.
The LP gas cylinder must be constructed and marked in accordance with the specifications for LP gas
cylinders of the U.S. Department of Transportation (DOT). The cylinder must be provided with a shut off
valve terminating in an LP gas supply cylinder valve outlet specified, as applicable, for connection type
QCC1 in the standard for compressed gas cylinder valve outlet and inlet connections ANSI/CGA-V-I.
POWER CABLE
(8 FT - 115 V PLUG)