Dacor DOP48M96DLS Range

User Manual - Page 48

For DOP48M96DLS.

PDF File Manual, 68 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
English48
Installation instructions
Installation instructions
Installing a 4-wire conduit
Aluminum building wire may be used but it must be rated for the correct amperage
and voltage. Connect wires according to this Step 4 depending on the number of wires.
Wire used, location and enclosure of splices, etc., must conform to good wiring
practices and local codes.
Ground strap
Ground plate
White
Black
Red
Neutral
terminal
Ground wire
(Green)
Wire
tips
White
Black
Red
1. Loosen the 3 lower terminal screws
from the terminal block. Remove the
ground screw and ground plate and
retain them.
2. Cut and discard the ground strap. Do
not discard any screws.
3. Insert the ground bare wire tip
between the range frame and the
ground plate (removed earlier) and
secure it in place with the ground
screw (removed earlier).
4. Insert the bare wire (white/neutral)
tip through the bottom center of the
terminal block opening.
5. Insert the two side bare wire tips into
the lower left and the lower right
terminal block openings.
6. Tighten the screws until the wire is
firmly secured (35 to 50 inch-lbs.). Do
not over-tighten the screws since it
could damage the wires.
Install_NY9900M_PRORANGE_DOP48M96DLM_DA_DG68-00936A-00_EN+MES+CFR.indb 48 2017-05-12  7:36:52