Installation requirements
Electrical requirements
Failure to follow these instructions can result in death, fire, or electrical shock.
WARNING
It is the owner’s responsibility to make sure that the electrical service meets electrical
requirements and that he electrical outlet has been properly installed by a licensed
electrician.
To reduce the risk of fire, electric shock, or personal injury:
All range
Do not use an extension cord or adapter plug with this range.
This range must be properly grounded.
Check with a qualified electrician if you are in doubt as to whether your range is
properly grounded.
Do not modify the range power plug. If it does not fit the outlet, have a proper outlet
installed by a qualified electrician.
All wiring and grounding must comply with local codes or, in the absence of local
codes, with the National Electrical Code, ANSI/NFPA No. 70 – Latest Revision (US), or
the Canadian Electrical Code CSA C22.1 – Latest Revisions and local codes.
Wiring diagram is located on the back of the range. (Inside of the cover back wire)
The range’s electronic ignition system will not operate if the outlet is not properly
polarized.
A dedicated circuit breaker is recommended.
Use the chart below to determine the minimum recommended dedicated circuit
protection.
KW Rating (240 V) Recommended Circuit Size (Dedicated)
7.3 KW - 9.6 KW 40 Amp
9.7 KW - 12.0 KW 50 Amp