Garland MPGD10S MP-GD-10-S 38" Moisture+ Deep Depth Full-Size Convection Oven with Solid State Controller, Two Speed Fan with 3/4 HP Fan Motor and Quartz Illumination, in Stainless Steel

User Manual - Page 45

For MPGD10S.

PDF File Manual, 80 pages, Download pdf file

Loading ...
Loading ...
Loading ...
Part # MPSM07 (03/24/08) Page 45
If the actual temperature inside the oven exceeds the
set temperature by 50°F, the display will show “HI TEMP
and the alarm will sound. The fan will continue to run,
however, power to the heaters will be cut.
If the actual temperature sensed inside the oven exceeds
575°F, the control will change to “HELP and the alarm will
sound continuously. All control operations will shut down
except the alarm.
NOTE: The control will need a complete power down and
restart (unplug/plug in oven) before any control functions
will become operational. If the problem persists, contact a
service technician.
In the event of a temperature probe failure, the control
will become inoperative and the display will show “PROBE
ERROR”. Once the problem is corrected, the control must
be cycled On/O (using the ON/OFF key) in order to
become operative again
DIAGNOSTIC PROCEDURES
Loading ...
Loading ...
Loading ...