en-us Installation and connection
Hot water connection *
Hot wat er connect i on
The dishwasher can be connected to cold or hot water
up to max. 140° F (60 °C). Connection to hot water is
recommended if the hot water can be supplied by
energetically favourable means and from a suitable
installation, e.g. solar heating system with circulation
line. This will save energy and time. The “Hot water”
setting allows you to adjust your dishwasher optimally to
operation with hot water. It is recommended to have a
water temperature (temperature of the incoming water)
of at least 104° F (40 °C) and no more than 140° F
(60 °C). It is not recommended to connect the
appliance to hot water if the water is supplied from an
electric boiler.
To change the setting:
1. Open the door.
2. Switch on ON/OFF switch (.
3. Press Info button ( 8 for 3 seconds until the
following text is indicated on the display window at
the top @:
Scroll with < >
Set with - +
Leave with t 3 sec.
4. Keep pressing the button > ` until water
connection appears of the display window at the top
@.
5. Make the selection with setting buttons + -X.
6. Press and hold the Info button (8 for 3 seconds.
The chosen setting has now been stored.
* optional feature which may or may not be included with
your dishwasher.
Electrical connection
Connect the appliance to an 120 V, 60 Hz alternating
current only, via a correctly installed outlet with
protective grounding conductor. See rating plate for
required fusing 9J.
The outlet must be near the appliance and freely
accessible after the installation.
If the plug is not freely accessible, an allpole
disconnector with a contact opening of at least 3 mm
must be fitted on the installation side to satisfy the
relevant safety instructions.
The connection may be modified by technicians only.
A power cord extension may be purchased from
customer service only.
Use only a residual current operated circuit-breaker
which features the symbol . Only this extension
guarantees compliance with the currently valid
regulations.
The appliance features a water damage protection
system. Please note the system will function only
when the power supply is connected.
Removing the appliance
Also observe the sequence of worksteps here.
1. Disconnect the appliance from the power supply.
2. Turn off the tap.
3. Undo the drain water and water supply connection.
4. Loosen fastening screws for the cabinet parts.
5. If fitted, remove the base panel.
6. Pull out the appliance, carefully pulling the hose
behind.