12 • EN
CHARGING PROGRAMS AND OPTIONS
Press the MODE-button to select between the charging programs and to add charging options. The lamps will indicate which
programs and options that are selected. The selected program will be memorised and restarted next time the charger is
connected.
CHARGING PROGRAMS
PROGRAM BATTERY SIZE (AH) EXPLANATION TEMP RANGE
1.2–14Ah
Small battery program, 0.8A
Use for smaller batteries.
-4°F–122°F
(-20°C–+50°C)
14–160Ah
Normal battery program, 4.3A
Use for normal sized batteries.
-4°F–122°F
(-20ºC–+50ºC)
CHARGING OPTIONS
OPTION EXPLANATION TEMP RANGE
Cold weather option
Use for charging at low temperatures and for power AGM batteries like Optima
®
and
Odyssey
®
. Cold weather option increases charging voltage
-4°F–+41°F
(-20ºC–+5ºC)
RECOND
Recond option
Use to return energy to empty batteries. Recond your battery once per year and after
deep discharge to maximise lifetime and capacity. The Recond option adds STEP6 to
the selected charging program.
-4°F–122°F
(-20ºC–+50ºC)