en Installation and connection
26
Technical specifications
Refrigerant, cubic capacity and further
technical specifications can be found on
the rating plate.
~ "Getting to know your appliance"
on page 29
Installing the appliance
Installation location
The more refrigerant an appliance
contains, the larger the room must be in
which the appliance is situated. In
rooms which are too small leaking
refrigerant can form a flammable gas-air
mixture.
Per 8 g of refrigerant the room must be
at least 1 m³ in size. The amount of
refrigerant in your appliance is indicated
on the rating plate inside the appliance.
~ "Getting to know your appliance"
on page 29
The weight of the appliance may be up
to 69 kg depending on the model.
Permitted room temperature
The permitted room temperature
depends on the climatic class of the
appliance.
Information on the climatic class can be
found on the rating plate.
~ "Getting to know your appliance"
on page 29
The appliance is fully functional within
the permitted room temperature.
If an appliance of climatic class SN is
operated at colder room temperatures,
the appliance will not be damaged up to
a room temperature of +5 °C.
Cavity depth
A cavity depth of 56 cm
is recommended for the appliance.
If the cavity depth is smaller – at least
55 cm – the energy consumption
increases slightly.
Climatic cate-
gory
Permitted room temperature
SN +10 °C ... 32 °C
N +16 °C ... 32 °C
ST +16 °C ... 38 °C
T +16 °C ... 43 °C