User Manual LG DLE7150W 7.3 Cu. Ft. Capacity Electric Dryer

LG DLE7150W 7.3 Cu. Ft. Capacity Electric Dryer - Use Manual - Use Guide PDF.
Documents: Go to download!
User Manual
  • User Manual - (English, French)
Specification
file thumbnail

OWNER'S MANUAL

PRODUCT FEATURES

Easy-to-Use Control Panel

An entire selection of user-friendly functions make operating the dryer easy.

Easy-Access Reversible Door

The wide-opening door provides easy access for loading and unloading. The door hinge can be reversed to adjust for installation location.

Flow SenseTM Duct Blockage Sensing System Indicator

The Flow SenseTM duct blockage sensing system detects and alerts you to restrictions in the installed household ductwork that reduce exhaust airflow through the dryer. If you see the alert: Clean or repair the ducts to remove the restrictions. Keep your ducts free of blockage to help increase efficiency and reduce long drying times caused by blocked ducts.

Smart DiagnosisTM

Should you experience any technical difficulty with your dryer, it has the capability of transmitting data via your telephone to the Customer Information Center. The call center agent records the data transmitted from your machine and uses it to analyze the issue, providing a fast and effective diagnosis.

PRODUCT OVERVIEW

Parts

Accessories

Optional Accessories

INSTALLATION

Installation Overview

Please read the following installation instructions first after purchasing this product or transporting it to another location.

Product Specifications

The appearance and specifications listed in this manual may vary due to constant product improvements.

Installation Location Requirements

The installation requires:

  • A location that allows for proper exhaust installation. A gas dryer must be exhausted to the outdoors. See Venting the Dryer.
  • A grounded electrical outlet located within 2 ft. (61 cm) of either side of the dryer. See Connecting Electric Dryers .
  • A sturdy floor to support the total dryer weight of 200 lb (90.7 kg). The combined weight of a companion appliance should also be considered.
  • No other fuel-burning appliance can be installed in the same closet as a dryer.

Do not operate the dryer at temperatures below 45 °F (7 °C). At lower temperatures, the dryer might not shut off at the end of an automatic cycle. This can result in longer drying times. The dryer must not be installed or stored in an area where it will be exposed to water and/or weather. Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, mobile homes or sleeping quarters. Contact your local building inspector.

Clearances

Installation Spacing for Recessed Area or Closet Installation

The following spacing dimensions are recommended for this dryer. This dryer has been tested for clearances of 1 inch (2.5 cm) on the sides and rear. Recommended clearances should be considered for the following reasons:

  • Additional clearances should be considered for ease of installation and servicing.
  • Additional clearances might be required for wall, door and floor moldings.
  • Additional clearances should be considered on all sides of the dryer to reduce noise transfer. For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.
  • Companion appliance spacing should also be considered.

Closet Ventilation Requirements

Closets with doors must have both an upper and lower vent to prevent heat and moisture buildup in the closet.

One upper vent opening with a minimum opening of 48 sq. in. (310 cm2 ) must be installed no lower than 6 feet above the floor. One lower vent opening with a minimum opening of 24 sq. in. (155 cm2 ) must be installed no more than one foot above the floor. Install vent grills in the door or cut down the door at the top and bottom to form openings. Louvered doors with equivalent ventilation openings are also acceptable.

Installation Spacing for Recessed Area or Closet

Installation Spacing for Cabinet

For cabinet installation with a door, minimum ventilation openings in the top of the cabinet are required.

Leveling the Dryer

1. Position the dryer in the final location. Check levelness of dryer from side to side. Repeat from front to back.

2. Use an adjustable wrench to turn the leveling feet. Unscrew the legs to raise the dryer or screw in the legs to lower it. Raise or lower with the leveling feet until the dryer is level from side to side and front to back. Make sure that all four leveling feet are in firm contact with the floor.

If you are installing the dryer on the optional pedestal, you must use the leveling feet on the pedestal to level the dryer. The dryer leveling feet should be fully retracted.

Reversing the Door

1. Open the door and remove the two plastic hole caps on the catch side by gently prying up with a flat blade screwdriver. Save these for step 6.

2. While supporting the door, remove the 4 screws, two from each hinge. Set the door aside face down on a protected surface to prevent damage to the door or the work surface.

3. With the door on a protected surface, remove all screws on each side of the door and lift off the inner door frame using a flat blade screwdriver. Remove the latch hook and blank and move them to the opposite side.

4. Remove the 4 screws securing the hinges to the door frame. Remove the two plastic cover caps. Reinstall the hinges and cover caps on the opposite sides from which they were removed.

5. With the hinges and cover caps in the new locations, remount the inner door frame onto the outer door frame with the screws removed in step 3 above.

6. Reinstall the door with the screws from steps 1,2.

7. Test the swing of the door to make sure the hinges and latch are properly aligned and that the door closes and latches correctly.

Installing the Side Vent Kit

The dryer is shipped to vent to the rear. It can also be configured to vent to the bottom or side (right-side venting is not available on gas models).

An adapter kit, part number 383EEL9001B, may be purchased from an LG retailer. This kit contains the necessary duct components to change the dryer vent location.

1. Remove the rear exhaust duct retaining screw. Pull out the exhaust duct.

Option 1: Side Venting

2. Press the tabs on the knockout and carefully remove the knockout for the desired vent opening (right-side venting is not available on gas models). Press the adapter duct onto the blower housing and secure to the base of the dryer as shown.

3. Preassemble a 4-inch (10.2 cm) elbow to the next 4-inch (10.2 cm) duct section, and secure all joints with duct tape. Be sure that the male end of the elbow faces AWAY from the dryer. Insert the elbow/duct assembly through the side opening and press it onto the adapter duct. Secure it in place with duct tape. Be sure that the male end of the duct protrudes 11⁄2 inches (3.8 cm) to connect the remaining ductwork. Attach the cover plate to the back of the dryer with the included screw.

Option 2: Bottom Venting

2. Press the adapter duct onto the blower housing and secure it to the base of the dryer as shown.

3. Insert the 4-inch (10.2 cm) elbow through the rear opening and press it onto the adapter duct. Be sure that the male end of the elbow faces down through the hole in the bottom of the dryer. Secure it in place with duct tape. Attach the cover plate to the back of the dryer with the included screw.

Venting the Dryer

Do not crush or collapse ductwork. Failure to follow these instructions may result in fire or death.

Do not allow ductwork to rest on or contact sharp objects. Failure to follow these instructions may result in fire or death.

If connecting to existing ductwork, make sure it is suitable and clean before installing the dryer.

Failure to follow these instructions may result in fire or death.

Venting must conform to local building codes.

Failure to follow these instructions may result in fire or death.

Gas dryers MUST exhaust to the outdoors.

Failure to follow these instructions may result in fire or death.

Use only 4-inch (10.2 cm) rigid, semi-rigid or flexible metal ductwork inside the dryer cabinet and for venting outside. Failure to follow these instructions may result in fire or death.

To reduce the risk of fire, combustion, or accumulation of combustible gases, DO

NOT exhaust dryer air into an enclosed and unventilated area, such as an attic, wall, ceiling, crawl space, chimney, gas vent, or concealed space of a building. Failure to follow these instructions may result in fire or death.

To reduce the risk of fire, DO NOT exhaust the dryer with plastic or thin foil ducting. Failure to follow these instructions may result in fire or death.

The exhaust duct must be 4 inches (10.2 cm) in diameter with no obstructions. The exhaust duct should be kept as short as possible. Make sure to clean any old ducts before installing your new dryer. Failure to follow these instructions may result in fire or death.

Rigid, semi-rigid or flexible metal ducting is recommended for use between the dryer and the wall. All non-rigid metal transition duct must be UL-listed. Use of other materials for transition duct could affect drying time. Failure to follow these instructions may result in fire or death.

DO NOT use sheet metal screws or other fasteners which extend into the duct that could catch lint and reduce the efficiency of the exhaust system. Secure all joints with duct tape. Failure to follow these instructions may result in fire or death.

Do not exceed the recommended duct length limitations noted in the chart. Failure to follow these instructions may result in extended drying times, fire or death.

Ductwork is not provided with the dryer. You should obtain the necessary ductwork locally.

The vent hood should have hinged dampers to prevent backdraft when the dryer is not in use.

Failure to follow these instructions may result in fire or death.

The total length of flexible metal duct must not exceed 8 ft. (2.4 m).

In Canada, only those foil-type flexible ducts, if any, specifically identified for use with the appliance by the manufacturer should be used.

In the United States, only those foil-type flexible ducts, if any, specifically identified for use with the appliance by the manufacturer and that comply with the Outline for Clothes Dryer Transition Duct, Subject 2158A, should be used.

Ductwork

Routing And Connecting Ductwork

Correct Venting

Incorrect Venting

Connecting Gas Dryers

Gas Supply Requirements

  • As shipped from the factory, this dryer is configured for use with natural gas (NG). It can be converted for use with propane (LP) gas.
  • Gas pressure must not exceed 8 inches cm) of water column for NG, or 13 inches cm) of water column for LP.
  • A qualified service or gas company technician must connect the dryer to the gas service.
  • Failure to follow these instructions may result in fire, explosion, or death.
  • Isolate the dryer from the gas supply system by closing its individual manual shutoff valve during any pressure testing of the gas supply at pressures greater than 1/2 psi (3.5 kPa).
  • Supply line requirements: Your laundry room must have a rigid gas supply line to the dryer.
  • In the United States, an individual manual shutoff valve MUST be installed within at least ft. (1.8 m) of the dryer, in accordance with the National Fuel Gas Code ANSI Z223.1 or Canadian gas installation code CSA B149.1.
  • A 1/8-inch (0.3 cm) NPT pipe plug must be installed. Failure to do so may result in fire, explosion, or death.
  • If using a rigid pipe, the rigid pipe should be inch IPS. If acceptable under local codes and ordinances and when acceptable to your gas supplier, 3/8-inch (1 cm) approved tubing may be used where lengths are less than 20 ft. m). Larger tubing should be used for lengths in excess of 20 ft. (6.1 m). Failure to do so may result in fire, explosion, or death.
  • Connect the dryer to the type of gas shown on the nameplate. Failure to do so may result in fire, explosion, or death.
  • To prevent contamination of the gas valve, purge the gas supply of air and sediment before connecting the gas supply to the dryer. Before tightening the connection between the gas supply and the dryer, purge remaining air until the odor of gas is detected. Failure to do so may result in fire, explosion, or death.
  • DO NOT use an open flame to inspect for gas leaks. Use a noncorrosive leak detection fluid.
  • Failure to do so may result in fire, explosion, or death.
  • Use only a new AGA- or CSA-certified gas supply line (in compliance with the Standard for Connectors for Gas Appliances, ANSI Z21.24 • CSA 6.10) with flexible stainless steel connectors.
  • Securely tighten all gas connections. Failure to do so may result in fire, explosion, or death.
  • Use Teflon tape or a pipe-joint compound that is insoluble in propane (LP) gas on all pipe threads. Failure to do so may result in fire, explosion, or death.
  • DO NOT attempt any disassembly of the dryer; disassembly requires the attention and tools of an authorized and qualified service technician or company. Failure to follow this warning may result in fire, explosion, or death.

Electrical Requirements for Gas Models Only

  • Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.
  • Failure to follow this warning may result in fire, explosion, or death.
  • For personal safety, this dryer must be properly grounded. Failure to follow this warning may result in fire, explosion, or death.
  • This dryer must be plugged into a 120-VAC,
  • Hz. grounded outlet protected by a ampere fuse or circuit breaker. Failure to follow this warning may result in fire, explosion, or death.
  • Where a standard 2-prong wall outlet is encountered, it is your personal responsibility and obligation to have it replaced with a properly grounded 3-prong wall outlet. Failure to follow this warning may result in fire, explosion, or death.

Connecting the Gas Supply

  • Installation and service must be performed by a qualified installer, service agency, or the gas supplier. Failure to do so may result in fire, explosion, or death.
  • Use only a new stainless steel flexible connector and a new AGA-certified connector.
  • Failure to do so may result in fire, explosion, or death.
  • A gas shutoff valve must be installed within 6 ft. m) of the dryer. Failure to do so may result in fire, explosion, or death.
  • The dryer is configured for natural gas when shipped from the factory. Make sure that the dryer is equipped with the correct burner nozzle for the type of gas being used (natural gas or propane gas). Failure to do so may result in fire, explosion, or death.
  • If necessary, the correct nozzle (for the LP nozzle kit, order part number 383EEL3002D) should be installed by a qualified technician and the change should be noted on the dryer.
  • Failure to do so may result in fire, explosion, or death.
  • All connections must be in accordance with local codes and regulations. Failure to do so may result in fire, explosion, or death.
  • Gas dryers MUST exhaust to the outdoors. Failure to do so may result in fire, explosion, or death.
  1. Make sure that the gas supply to the laundry room is turned OFF and the dryer is unplugged.Confirm that the type of gas available in your laundry room is appropriate for the dryer.
  2. Remove the shipping cap from the gas fitting at the back of the dryer. Be careful not to damage the threads of the gas connector when removing the shipping cap.
  3. Connect the dryer to your laundry room’s gas supply using a new flexible stainless steel connector with a 3/8-inch NPT fitting.
  4. Securely tighten all connections between the dryer and your laundry room’s gas supply.
  5. Turn on your laundry room’s gas supply.
  6. Check all pipe connections (both internal and external) for gas leaks with a noncorrosive leak- detection fluid.
  7. Proceed to Venting the Dryer.

High-Altitude Installations

The BTU rating of this dryer is AGA-certified for elevations below 10,000 feet.

If your gas dryer is being installed at an elevation above 10,000 feet, it must be derated by a qualified technician or gas supplier.

Connecting Electric Dryers

Electrical Requirements for Electric Models Only

This dryer must be connected to a grounded metal, permanent wiring system, or an equipment-grounding conductor must be run with the circuit conductors and connected to the equipment-grounding terminal or lead on the dryer. Failure to do so may result in fire, explosion, or death.

The dryer has its own terminal block that must be connected to a separate 230 VAC, 60-Hertz, single-phase circuit, fused at 30 amperes (the circuit must be fused on both sides of the line). ELECTRICAL SERVICE FOR THE DRYER SHOULD BE OF THE MAXIMUM RATE VOLTAGE LISTED ON THE NAMEPLATE. DO NOT CONNECT THE DRYER TO 110-, 115-, OR 120- VOLT CIRCUIT. Failure to follow these instructions may result in fire, explosion, or death.

If the branch circuit to dryer is 15 ft. (4.5 m) or less in length, use UL (Underwriters Laboratories) listed No. 10 AWG wire (copper wire only), or as required by local codes. If over 15 ft. (4.5 m), use UL-listed No. 8 AWG wire (copper wire only), or as required by local codes. Allow sufficient slack in wiring so the dryer can be moved from its normal location when necessary. Failure to do so may result in fire, explosion, or death.

The power cord (pigtail) connection between the wall receptacle and the dryer terminal block

IS NOT supplied with the dryer. Type of pigtail and gauge of wire must conform to local codes and with instructions on the following pages.

Failure to follow these instructions may result in fire, explosion, or death.

Do not modify the plug and internal wire provided with the dryer.

The dryer should be connected to a 4-hole outlet.

If the plug does not fit the outlet, a proper outlet will need to be installed by a qualified electrician.

Final Installation Check

Once you have completed the installation of the dryer and it is in its final location, confirm proper operation with the following tests and the Installation Test (Duct Check) on the following page.

Testing Dryer Heating

GAS MODELS

Close the dryer door, press the POWER button to turn the dryer on, and start the dryer on a heat setting.

When the dryer starts, the igniter should ignite the main burner.

ELECTRIC MODELS

Close the dryer door, press the POWER button to turn the dryer on, and start the dryer on a heat setting.

The exhaust air should be warm after the dryer has been operating for 3 minutes.

Checking Airflow

Effective dryer operation requires proper airflow.

The adequacy of the airflow can be measured by evaluating the static pressure. Static pressure in the exhaust duct can be measured with a manometer, placed on the exhaust duct approximately 2 ft. (60.9 cm) from the dryer. Static pressure in the exhaust duct should not exceed 0.6-inch (1.5 cm). The dryer should be checked while the dryer is running with no load.

Checking Levelness

Once the dryer is in its final location, recheck the dryer to be sure it is level. Make sure it is level front to back and side to side, and that all four leveling feet are firmly on the floor.

Checking Venting

Vent ductwork should be checked for lint buildup and cleaned at least once per year. If any noticeable reduction in drying performance occurs, check duct for obstructions and blockages.

Installation Test (Duct Check)

Once you have completed the installation of the dryer, use this test to make sure the condition of the exhaust system is adequate for proper operation of the dryer. This test should be performed to alert you to any serious problems in the exhaust system of your home.

This dryer features Flow SenseTM, an innovative sensing system that automatically detects blockages and restrictions in dryer ductwork.

Keeping ductwork clean of lint buildup and free of restrictions allows clothes to dry faster and reduces energy use.

To activate the installation test:

1. Remove the drying rack and literature, and then close the door.

Do not load anything in the drum for this test, as in may affect the accuracy of the results.

2. Press and hold the POWER, Temp., and Wrinkle Care buttons until and a usage count alternate in the display. (The usage count indicates the number of cycles run with no load during the last 5 cycles.)

3. Press the START/PAUSE button.

The dryer will start the test, which will last about minutes. The heat will be turned on and the temperatures in the drum will be measured and displayed. A chime sounds when the test portion of the cycle is complete.

4. Check the display for results.

During the test cycle, monitor the Flow SenseTM display on the control panel. If the Flow SenseTM LED has not turned on, when the cycle ends, the exhaust system is adequate. If the exhaust system is severely restricted, the Flow SenseTM LED will turn on. Other problems may also be shown with error codes. See the chart below for error code details and solutions.

The Flow SenseTM LED indicates that the exhaust system is severely restricted. Have the system checked immediately, as performance will be poor.

5. End of cycle.

At the end of the test cycle, will display. The test cycle will end and the dryer will shut off automatically after a short delay.

  • Check the error code before you call for service

  • Check the duct condition

If the Flow SenseTM LED is turned on, check the exhaust system for restrictions and damage. Repair or replace the exhaust system as needed.

Restricted or Blocked Airflow

Avoid long runs or runs with multiple elbows or bends.

Check for blockages and lint buildup.

Make sure the ductwork is not crushed or restricted.

OPERATION

Using the Dryer

1. Clean the Lint Filter

If the lint filter has not already been cleaned, lift out the filter and remove the lint from the last load. This will help ensure the fastest and most efficient drying perfor- mance. Make sure to reinstall the filter, pressing down until it clicks firmly into place. The dryer will not operate without the lint filter in place.

2. Load the Dryer

Load the dryer with the wet laundry from the washer. If the load is extra large, you may need to divide it into smaller loads for proper performance and fabric care.

3. Turn on The Dryer

Press the POWER button to turn ON the dryer. The cycle LEDs will illuminate and a chime will sound.

4. Select a Cycle

Turn the cycle selector knob in either direction until the LED for the desired cycle is on. The preset temperature, dry level, and option settings for that cycle will be shown. Default settings for the selected cycle can now be changed if desired. Refer to the Cycle Setting and Options page for details.

5. Begin the Cycle

Press the START/PAUSE button to begin the cycle. The cycle can be paused at any time either by opening the door or by pressing the START/PAUSE button.

If the cycle is not restarted within 60 minutes of being paused, the dryer will shut off and the settings will be lost.

6. End of Cycle

When the cycle is finished, the chime will sound. Immediately remove your clothing from the dryer to reduce wrinkling. If Wrinkle Care is selected, the dryer will tumble briefly every few minutes to help prevent wrinkles from setting in the clothes.

Check the Lint Filter Before Every Load

Always make sure the lint filter is clean before starting a new load; a clogged lint filter will increase drying time. To clean, pull the lint filter straight up and roll any lint off the filter with your fingers. Do not rinse or wash the filter to remove lint. Push the lint filter firmly back into place. See Regular Cleaning for more information.

Always ensure the lint filter is properly installed before running the dryer. Running the dryer with a loose or missing lint filter will damage the dryer and articles in the dryer.

Sorting Loads

Fabric Care Labels

Most articles of clothing feature fabric care labels that include instructions for proper care.

Group Similar Items

For best results, sort clothes into loads that can be dried with the same drying cycle.

Different fabrics have different care requirements, and some fabrics will dry more quickly than others. For best fabric care results, always dry fabrics with similar care requirements together.

Loading the Dryer

Control Panel

1. POWER Button

Press to turn the dryer ON. Press again to turn the dryer OFF.

2. Cycle Selector Knob

Turn this knob to select the desired cycle. Once the desired cycle has been selected, the standard presets are shown in the display. On Manual Dry cycles, these settings can be adjusted using the cycle modifier buttons any time before starting the cycle.

3. START/PAUSE Button

Press this button to start the selected cycle. If the dryer is running, use this button to pause the cycle without losing the current settings.

4. Time and Status Display

The display shows the settings, estimated time remaining, options, and status messages for the dryer.

5. More Time/Less Time Buttons

Use these buttons with the Time Dry and other

Manual Dry cycles to adjust the drying time. Press the

More Time button to increase the selected manual cycle time by 1 minute; press the Less Time button to decrease the cycle time by 1 minute.

6. Cycle Modifier Buttons

Use these buttons to select the desired cycle settings for the selected cycle. The current settings are shown in the display. Press the button for that modifier to select other settings.

7. Cycle Option Buttons

The option buttons allow you to select additional cycle options. Certain buttons also allow you to activate special functions by pressing and holding the button for 3 seconds.

8. Clean Filter Reminder

The display will show Clean Filter when the dryer is turned on as a reminder to check the filter. It turns off when the START/PAUSE button is pressed.

9. Cycle Completion Indicator with Check Filter Reminder

This portion of the display shows which stage of the drying cycle is currently underway (Dry, Cool).

10. Estimated Time Remaining

This display shows the estimated time remaining for SENSOR DRY cycles or the actual time remaining for Time Dry or MANUAL DRY cycles.

11. Flow SenseTM Duct Blockage Sensing System Indicator

The Flow SenseTM duct blockage sensing system detects and alerts you to blockages in the ductwork that reduce exhaust flow from the dryer. Maintaining a clean exhaust system improves operating efficiency and helps minimize service calls, saving you money.

12. Control Lock Indicator

When Control Lock is set, the Control Lock indicator appears and all buttons are disabled except the POWER button. This prevents children from changing settings while the dryer is operating.

13. Damp Dry Signal Indicator

The dryer will signal when the load is approximately dry. This allows you to remove faster- drying lightweight items or items that you would like to iron or hang while still slightly damp.

Cycle Guide

Sensor Dry Cycles

Sensor dry cycles utilize LG’s unique dual sensor system to detect and compare the moisture level in clothes and in the air and adjust the drying time as needed to ensure superior results. The dryer automatically sets the dryness level and temperature at the recommended setting for each cycle. The estimated time remaining will be shown in the display.

Manual Dry Cycles

Use manual dry cycles to select a specific amount of drying time and a drying temperature. When a manual dry cycle is selected, the Estimated Time

Remainng display shows the actual time remaining in your cycle. You can change the actual time in the cycle by pressing More Time or Less Time.

Cycle Settings and Options

Cycle Modifier Buttons

SENSOR DRY cycles have preset settings that are selected automatically. MANUAL DRY cycles have default settings, but you may also customize the settings using the cycle modifier buttons. Press the button for that option to view and select other settings.

Dry Level

Selects the level of dryness for the cycle. Press the Dry Level button repeatedly to scroll through available settings.

  • This option is only available with SENSOR DRY cycles.
  • The dryer will automatically adjust the cycle time. Selecting Very Dry will increase the cycle time, while Damp Dry will decrease the cycle time.
  • Use a Damp Dry setting for items that you wish to iron.

Temp.

Adjusts the temperature setting. This allows precise care of your fabrics and garments. Press the Temp. button repeatedly to scroll through available settings.

Time Dry

Allows you to manually select the drying time, from 20 to 60 minutes, in 20-minute increments. Use this for small loads or to remove wrinkles.

More Time/Less Time

Use the More Time/Less Time buttons to add or reduce the drying time of a MANUAL DRY cycle in 1-minute increments.

Cycle Option Buttons

The dryer features several additional cycle options to customize cycles to meet individual needs. Certain option buttons also feature a special function that can be activated by pressing and holding that option button for 3 seconds. (See Special Functions on the following page for details.)

Adding Cycle Options to a Cycle:

  1. Turn on the dryer and turn the cycle selector knob to select the desired cycle.
  2. Use the cycle modifier buttons to adjust the settings for that cycle.
  3. Press the cycle option button(s) for the option you would like to add. A confirmation message is shown in the display.
  4. Press the START/PAUSE button to start the cycle. The dryer starts automatically.

Wrinkle Care

Selecting this option will tumble the load periodically for up to 3 hours after the selected cycle, or until the door is opened. This is helpful in preventing wrinkles when you are unable to remove items from the dryer immediately.

Energy Saver (on some models)

This option helps to reduce energy consumption in the Normal cycle, depending on the load size.

When the Energy Saver option is selected, the cycle begins with an air dry section and the drying time is increased.

Special Functions

Some cycle option buttons also activate secondary functions. These special functions are marked with an asterisk (*). Press and hold the option button marked with the special function to activate it.

Control Lock

Use this option to prevent unwanted use of the dryer or to keep cycle settings from being changed while the dryer is operating.

Press and hold the button marked *Control Lock for seconds to activate or deactivate the Control Lock function. The Control Lock icon will be shown in the display, and all controls will be disabled except the POWER button.

Damp Dry Signal

With this option, the dryer will signal when the load is approximately 80% dry. This allows you to remove faster- drying lightweight items or items that you would like to iron or hang while still slightly damp.

Default On/Off

This option allows the Energy Saver settings to be changed. To run a Normal cycle without the Energy Saver option, press and hold the Energy Saver button for three seconds. ON or OFF appears in the display.

SIGNAL

Press and hold the Dry Level button for 3 seconds to adjust the volume of the signal. Press and hold the button repeatedly to adjust the volume of the melody.

When no signal is heard, the signal is off. The volume settings are ON – OFF. The signal volume can be adjusted at any time as long as the dryer is turned ON.

SMART FUNCTIONS

LG ThinQ Application

Installing the LG ThinQ Application

Search for the LG ThinQ application from the Google

Play Store or Apple App Store on a smartphone.

Follow instructions to download and install the application.

LG ThinQ Application Features

Smart DiagnosisTM

This function provides useful information for diagnosing and solving issues with the appliance based on the pattern of use.

Smart DiagnosisTM Feature

This feature is only available on the models with or logo.

Use this feature to help you diagnose and solve problems with your appliance.

Using Audible Diagnosis to Diagnose Issues

Follow the instructions below to use the audible diagnosis method.

  • Launch the LG ThinQ application and select the Smart DiagnosisTM feature in the menu.

Follow the instructions for audible diagnosis provided in the LG ThinQ application.

1. Press the Power button to turn on the appliance.

  • Do not press any other buttons.

2. Hold the mouthpiece of your phone in front of the or logo.

3. Press and hold the Temp. button for 3 seconds or longer while continuing to hold your phone to the logo.

4. Keep the phone in place untill the tone transmission has finished. The display will count down the time. Once the cont down is over and the tones have stopped, the diagnosis will be displayed in the application.

MAINTENANCE

Regular Cleaning

Cleaning the Exterior

Proper care of your dryer can extend its life. The outside of the machine can be cleaned with warm water and a mild, nonabrasive household detergent.

Immediately wipe off any spills with a soft, damp cloth.

Cleaning the Interior

Wipe around the door opening and seal with a soft, damp cloth to prevent lint and dust buildup that could damage the door seal.

Clean the window with a soft cloth dampened with warm water and a mild, nonabrasive household detergent, then wipe dry.

The stainless steel drum can be cleaned with a conventional stainless steel cleaner, used according to the manufacturer’s specifications. Never use steel wool or abrasive cleansers; they may scratch or damage the surface.

Cleaning Around and Under the Dryer

Vacuum lint and dust from around the dryer and underneath it regularly. Vent ductwork should be checked for lint buildup and cleaned at least once per year. If any noticeable reduction in airflow or drying performance occurs, immediately check ductwork for obstructions and blockages.

Maintaining Ductwork

Vent ductwork should be checked for lint buildup once per month and cleaned at least once per year. If any noticeable reduction in airflow or drying performance occurs, immediately check ductwork for obstructions and blockages. Contact a qualified technician or service provider.

Cleaning the Lint Filter

Always clean the lint from the filter after every cycle.

To clean, open the dryer door and pull the lint filter straight up. Then:

1. For everyday cleaning, roll any lint off the filter with your fingers, or

2. Vacuum the lint filter.

3. If the lint filter has become very dirty or clogged with fabric softener, wash the lint filter in warm, soapy water and allow it to dry thoroughly before reinstalling.

TROUBLESHOOTING

FAQs: Frequently Asked Questions

Q: When I press a button, why does my dryer beep and then nothing happens?

A: The Control Lock feature is turned on. To turn off Control Lock, turn the dryer on, then press and hold the button that has *Control Lock on or under it for 3 seconds.

Q: Why does my dryer take so long to dry clothes?

A: Proper airflow is critical to the efficient operation of clothes dryers. A lint filter which is full of lint or clogged with fabric softener sheet residue can reduce the airflow to the point that the time required to dry clothing will be greatly increased. Another factor affecting dry time is your home exhaust system. An exhaust system which is dirty and clogged with lint, or is excessively long, needs to be professionally cleaned or repaired.

Q: Why does my dryer start by itself every few minutes?

A: This is how the Wrinkle Care feature works. The dryer runs briefly every few minutes for up to 3 hours after the cycle finishes. This feature is designed to help prevent wrinkles from setting in when the dryer is not unloaded immediately after the cycle is finished.

Before Calling for Service

This dryer is equipped with an automatic error-monitoring system to detect and diagnose problems at an early stage. If the dryer does not function properly or does not function at all, check the following before you call for service.

Operation

Problem Possible Cause Solutions
The Flow SenseTM indicator remains active after clearing the restriction in the venting. After clearing the restriction, the Flow SenseTM system requires multiple, consecutive cycles to determine that the performance value has improved before the Flow SenseTM indicator is reset. If the Flow SenseTM indicator remains active for more than five cycles after the restriction has been cleared, call for service.
Dryer will not turn on

Power cord is not properly plugged in.

Make sure that the plug is securely plugged into a grounded outlet matching
the dryer’s rating plate.
House fuse is blown, circuit breaker has tripped, or power outage has occurred. Reset circuit breaker or replace fuse. Do not increase fuse capacity. If the problem is a circuit overload, have it corrected by a qualified electrician.
Dryer does not heat House fuse is blown, circuit breaker has tripped, or power outage has occurred. Reset circuit breaker or replace fuse. Do not increase fuse capacity. If the problem is a circuit overload, have it corrected by a qualified electrician.
Gas supply or service is turned
off (gas models only).
Confirm that the house gas shutoff and the dryer gas shutoff valves are both fully open. Even if gas is not supplied to the dryer, it will run and display error code. Verify that other gas appliances in the home are working normally.
Energy Saver option selected
(on some models)
If using the Cotton/Normal cycle, deselect the energy saver option. The Energy Saver option is selected by default. This option reduces energy use by adding an air dry section to the beginning of the cycle. It is normal to feel no heat at the beginning of the cycle while in Energy Saver mode.
Display show error code nP Electric dryer power cord is not connected correctly, or house power supply is incorrect. Check the power supply or the connection of the power cord to the terminal block.
Display show error code gAS Gas supply or service turned off (gas models only). Confirm that house gas shutoff and the dryer gas shutoff are both fully open.
Clothes take too long to dry Exhaust ducts are blocked, dirty, or duct run is too long. Confirm that the exhaust duct is properly configured and free of debris, lint, and obstructions. Make sure that outside wall dampers can open properly and are not blocked, jammed, or damaged.
Load is not properly sorted. Separate heavy items from lightweight items. Larger and heavier items take longer to dry. Light items in a load with heavy items can fool the sensor because the light items dry faster.
Clothes take too long to dry Large load of heavy fabrics. Heavy fabrics take longer to dry because they tend to retain more moisture. To help reduce and maintain more consistent drying times for large and heavy fabrics, separate these items into smaller loads of a consistent size.
Dryer controls are not set
properly.
Use the appropriate control settings for the type of load you are drying. Some loads may require an adjustment of the dry level setting for proper drying.
Lint filter needs to be cleaned. Remove the lint from the filter before
every load. With the lint removed, hold

See other models: 24QP550-B 27MP500-B MS2597OBC 65NANO80TNA LSGL6335D
the filter up to a light to see if it is dirty or clogged. With some loads that produce high amounts of lint, such as new bath towels, it may be necessary to pause the cycle and clean the filter during the cycle.
House fuse is blown, circuit
breaker has tripped, or power outage has occurred.
Reset circuit breaker or replace fuse. Do not increase fuse capacity. If the problem is a circuit overload, have it corrected by a qualified electrician.
Dryer is overloaded. Divide extra large loads into smaller
loads for better drying performance and efficiency.
Dryer is underloaded. If you are drying a very small load, add a few extra items to ensure proper tumbling action. If the load is very small and you are using SENSOR DRY cycles, the electronic control cannot properly sense the dryness of the load and may shut off
too soon. Use TIME DRY or add some
extra wet clothes to the load.
Clothes take too long to dry Energy Saver option selected (on some models) If using the Cotton/Normal cycle, deselect the Energy Saver option. This option reduces energy use by adding an air dry section to the beginning of the cycle.
Drying time is not consistent Heat settings, load size, or
dampness of clothing is not
consistent.
The drying time for a load will vary
depending on the type of heat used
(electric, natural gas, or LP gas), the
size of the load, the type of fabrics, the wetness of the clothes, and the condition of the exhaust duct and lint filter. Even an unbalanced load in the washer can cause poor spinning, resulting in wetter clothes which will take longer to dry.

Performance

Problem Possible Cause Solutions
Greasy or dirty spots on clothes Fabric softener used incorrectly. Confirm and follow the instructions provided with your fabric softener.
Clean and dirty clothes are being dried together. Use your dryer to dry only clean items. Soil from dirty clothes can transfer to the clean clothes in the same or later loads.
Clothes were not properly cleaned or rinsed before being
placed in the dryer.
Stains on dried clothes could be stains
that were not removed during the washing
process. Make sure that clothes are being
completely cleaned or rinsed according
to the instructions for your washer and
detergent. Some difficult soils may require
pre-treating prior to washing.
Clothes are wrinkled

Clothes dried too long (over dried).

Over drying a load of laundry can lead to
wrinkled clothes. Try a shorter drying time
or LESS DRY setting and remove items
while they still retain a slight amount of
moisture.
Clothes left in dryer too long after cycle ends. Use the WRINKLE CARE option. This
feature will tumble the clothes briefly
every few minutes for up to 3 hours to
help prevent wrinkling.
Clothes are shrinking

Garment care instructions are not being followed.

To avoid shrinking your clothes, always
consult and follow fabric care instructions.
Some fabrics will naturally shrink when
washed. Other fabrics can be washed but
will shrink when dried in a dryer. Use a
low or no heat setting.
Lint on clothes Lint filter not cleaned properly. Remove the lint from the filter before
every load. With the lint removed, hold
the filter up to a light to see if it is dirty
or clogged. If it looks dirty, follow the
cleaning instructions. With some loads
that produce high amounts of lint, it may
be necessary to clean the filter during the
cycle.
Laundry not sorted properly. Some fabrics are lint producers (i.e., a
fuzzy white cotton towel) and should be
dried separately from clothes that are lint
trappers (i.e., a pair of black linen pants).
Excess static in clothes. Use a fabric softener to reduce static
electricity. Be sure to follow the
manufacturer’s instructions. Overdrying
a load of laundry can cause a buildup of
static electricity. Adjust settings and use a
shorter drying time, or use SENSOR DRY
cycles.
Dryer is overloaded.

Divide extra large loads into smaller loads for drying.

Tissue, paper, etc., left in pockets.

Check pockets thoroughly before washing and drying clothes.

Excess static in clothes
after drying
Fabric softener is not used or used incorrectly. Use a fabric softener or the STATIC
SHIELD option, if equipped, to reduce
static electricity. Be sure to follow the
manufacturer’s instructions.
Clothes dried too long
(overdried).
Overdrying a load of laundry can cause
a buildup of static electricity. Adjust
settings and use a shorter drying time, or
use AUTO DRY cycles. Select a LESS
DRY setting on SENSOR DRY cycles, if
necessary.
Drying synthetics, permanent press, or synthetic blends. These fabrics are naturally more prone to
static buildup. Try using fabric softener, or
use LESS DRY and/or shorter TIME DRY
time settings.
Clothes have damp spots after a SENSOR DRY cycle. Very large load or very small load. Single large item such as a blanket or comforter.

Single large item such as a
blanket or comforter.

If items are too tightly packed or too
sparse the sensor may have trouble
reading the dryness level of the load. Use
a Time Dry cycle for very small loads.
Large, bulky items such as blankets
or comforters can sometimes wrap
themselves into a tight ball of fabric. The outside layers will dry and register on the sensors, while the inner core remains damp. When drying a single bulky item, it
may help to pause the cycle once or twice and rearrange the item to unwrap and expose any damp areas.
To dry a few remaining damp items from
a very large load or a few damp spots
on a large item after a sensor cycle has
completed, empty the lint trap, then set a
Time Dry cycle to finish drying the item(s).

Error Codes

Problem Possible Cause Solutions
Error code: tE1 through tE7 Temperature sensor failure. Turn off the dryer and call for service.
Display shows error
code: PS (electric
dryers only)
Power cord is connected
incorrectly.
Check the connection of the power cord to the terminal block.
*Flow SenseTM indicator shows four bars during
the drying cycle or the
display shows "d80"
after drying
* This warning light
is not a dryer failure
and is not covered by
the dryer warranty.
Contact a duct cleaning
service to set up an
appointment to have
your exhaust system
cleaned and inspected.
Exhaust system is too long or has too many turns/restrictions. Install a shorter or straighter duct run. See
the Installation Instructions for details.
Partial blockage of the ductwork due to lint buildup or other foreign object. Ductwork should be checked/cleaned immediately. Dryer can be used in this condition, but drying times will be longer and energy consumption will increase.
The appliance has detected a restriction in the external dryer
venting.
If exhaust restrictions are sensed by the Flow SenseTM system, the indicator will remain on for 2 hours after the end of the cycle. Opening the door or pressing the POWER button will turn off the display.
The Flow SenseTM
indicator remains
active after clearing
the restriction in the
venting.
After clearing the restriction, the
Flow SenseTM system requires multiple, consecutive cycles to
determine that the performance
value has improved before the Flow SenseTM indicator is reset.
If the Flow SenseTM indicator remains
active for more than five cycles after
the restriction has been cleared, call for
service.

indicator light is on during the drying cycle

Lint filter not cleaned properly. Remove the lint from the filter before
every load. With the lint removed, hold
the filter up to a light to see if it is dirty or
clogged. If it looks dirty, follow the cleaning instructions. With some loads that produce high amounts of lint, it may be necessary to clean the filter during the cycle.

The display shows d90, d95

The duct work is about 90%-95% blocked.(“d90” or “d95” error
code is displayed for 2 hours only)

House exhaust system blocked.

Do not use the dryer until the exhaust
system has been cleaned and/or repaired.
Using the dryer with a severely restricted
exhaust is dangerous and could result in
a fire or other property damage.
Check the outside dryer vent while the
dryer is operating to make sure there is
strong airflow.
If the exhaust system is extremely long,
have it repaired or rerouted.
Keep the area around the dryer clean and
free of clutter.
Check vent hood for damage or lint
clogging.
Make sure the area around the vent hood
is clear.


LG Electronics DLE7150W | Pages: 92 | Created on: 2021-01-06 | File type: PDF | Filename: 72913313_dle7150w.pdf | Size: 13.27 MB | Language: English, French

Download User Manual

Specs Sheet

  • Capacity: 7.3 cu.ft.
  • W x H x D: 27” x 44 1/4” x 29 1/2”(50 1/4” D with door open)
  • Weight: 114.9 lbs
  • Voltage: 240V
  • Amperage: 30 Amps

Product Infomation and Reviews - DLE7150W photo

DLE7150W Photo

LG Electronics in United States

(800) 243-0000 Consumer (7am-midnight CST) (888) 865-3026 Commercial (8am-6pm CST)

LG Electronics DLE7150W Questions and Answers

Find answers or Ask a question.
  • Total questions: 1
  • Questions unAnswered : 1

#1 What are the Dimensions ?
DIMENSIONS (WXHXD)
27” x 44 1/4” x 29 1/2”(50 1/4” D with door open)

#2 What is the warranty?
Parts & Labour: 1 Year
Drum: 3 Years