29
INFORMATION REGARDING THE INSTALLATION OF THE INDOOR UNIT
INSTALLING THE REAR PANEL
1. Always mount the rear panel horizontally.
Due to the water tray within the indoor unit
we would advise that the outlet of the water
tray should be fractionally lower when
installing as this will aid drainage of the
condensate collected.
2. Fix the rear panel on the wall with screws.
3. Be sure that the rear panel has been fixed
firmly enough to withstand the weight of an
adult (60Kg), furthermore the weight should
be evenly shared by each screw.
INSTALLING THE PIPING HOLE
1. Make the piping hole (55mm diameter) in the wall at
a slight downward slant to the outdoor side (To aid
drainage of the condensate).
2. Insert the piping-hole sleeve into the hole to prevent
the connecting piping and wiring from been damaged
when passing through the hole.
The piping can be lead out on the right,
left or directly behind the indoor unit as
seen in fig. 1. Please cut off the pipe hole
guards if you are changing the pipe
position. The unit also features
alternative guards for more pipe
positioning.
Make sure that the drain pipe is
underneath the pipelines. (Fig.3) (When
the drain pipe passes the room interior,
some condensed water might occur to its
surfaces if the humidity is very high).
Tidy up the copper pipes, electrical
cables and water drains and pass them
through the wall hole drilled earlier (fig.2).
Hang the mounting slots of the indoor
unit on the wall mounting bracket making
sure is tight in place (fig.3) so that the
hooks at the bottom of the indoor unit
match the hooks of the wall mounting
bracket (fig.4)
Loading ...
Loading ...
Loading ...