Loading ...
Loading ...
Loading ...
9
8
Problem Possible Reason Solution
Food is not cooking
or is taking too long
Burner has gone out Check that the gas bottle is not empty and
re-ignite the burner
Cooking surface was not given enough time
to warm up before the food was applied
Remove the food and give the burner time
to warm the cooking surface (5-10 minutes)
There is too much food on the cooking
surface
Cook smaller portions
Burner operation
OPERATING PROCEDURE
Burn-off
The cooking surface does not need any burn-off time
after first use.
Preheating
It is necessary to preheat the barbecue for at least 5
minutes before cooking certain foods, depending on the
type of food and the cooking temperature. Food that
requires a low cooking temperature, needs only a period
of 2-3 minutes preheating.
Cooking Temperatures
‘HIGH’ setting - Use this setting only for fast warm up, for
searing steaks and chops, and for burning food residue
from the grill plates after cooking is over. Rarely, if ever,
do you use the ‘HIGH’ setting for extended cooking.
‘MEDIUM’ setting (mid-way between ‘HIGH’ and ‘LOW’).
Use this setting for most grilling, and for cooking
hamburgers and vegetables.
‘LOW’ setting - Use this setting when cooking very lean
cuts such as fish.
These temperatures vary with outside temperature and
the amount of wind.
Roasting
For best results when roasting remove the hotplate and
centre the grill. The outer two burners should be used on
the low to medium setting.
Adjust the control knob to maintain the temperature
around the medium mark.
Approximate Cooking Time
The table below shows approximate cooking times with
the control set to ‘MEDIUM’ temperature.
Barbecue Roasts Minutes
Chicken & Rare Beef
(approx.)
45 minutes per Kg
Beef & Medium Lamb
(approx.)
60 minutes per Kg
Pork & Well Done Beef/
Lamb (approx.)
75 minutes per Kg
If the appliance has excessively yellow flames or cannot
be adjusted to perform correctly call 1300 174 876.
Nominal Hourly Gas Consumption
BBQ
Model No
Gas Type
Number
of BBQ
Burners
Injector
Size Main
Burners
Injector
Size Side
Burner
Injector
Size Rear
Burner
Total Gas
Consumption
MJ/h
Gas
Pressure
kPa
BQ1090
Propane
6 Ø1.05mm Ø1.15mm Ø1.05mm
100 MJ/h 2.75 kPa
MJ/h each 12.0 MJ/h 15.0 MJ/h 13.0 MJ/h
Natural
Gas
6 Ø1.75mm Ø1.75mm Ø1.80mm
112 MJ/h 1.0 kPa
MJ/h each 14 MJ/h 14 MJ/h 14 MJ/h