17
16
NATURAL GAS CONVERSION
TO BE INSTALLED ONLY ON OR IN A
NON-COMBUSTIBLE ENCLOSURE
Note: Recommended clearances must be maintained.
Tools Required:
7mm Drill, Thin (2.5mm diameter) flat Screw Driver,
Adjustable spanner, Phillips head screw driver.
GAS PIPING
1. THIS APPLIANCE IS ONLY TO BE INSTALLED
BY AN AUTHORISED PERSON.
2. Check with local and state plumbing and heating
codes regarding sizing of the gas lines.
3. All gas pipe connections must be sealed with a gas
pipe compound resistant to Natural Gas.
4. Installation of a drip leg if required in the gas supply
line must conform to AS5601.
5. When checking for gas leaks, do not use an open
flame. Use a soap and water solution and check for
bubbles indicating gas leakage.
6. Installation of 1/8” NPT plugged tapping, accessible
for test gauge connections, is required upstream of
the gas supply connection.
Warning
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage. Read
the instructions thoroughly before installing or servicing
this equipment.
Overall Dimensions
Length Width Height
BQ1090 1470mm 620mm 1210mm
SERVICING INSTRUCTIONS
Appliances should be serviced at least annually and
servicing must only be carried out by a Licensed Plumber
or Authorised Person.
Clean the Burner Ports and top with a Soft Brush.
Inspect and clean all combustion air inlets, then replace
the Burner ensuring it is firmly secured.
Minimum Clearance for Ventilation:
Rear 50 mm Side 50 mm
NOTE TO THE INSTALLER
1. The injector size is increased by removing the
Propane Nozzle (outer brass cap) and leaving the
Natural Gas Nozzle in place. Ensure the Natural gas
nozzle is still tight and in correct position; and the
hole size is correct.
2. To adjust the low/turndown flame setting remove
the main burner and side burner control knobs using
a long thin blade screwdriver to access the “LOW”
adjustment screw down the centre of the valve
spindle, turn the screw fully clockwise until it stops
then anti clockwise 1/8 of a turn.
TEST OPERATION OF APPLIANCE BEFORE LEAVING.
If the appliance has excessively yellow flames or cannot
be adjusted to perform correctly call 1300 174 876.
WARNING
Improper installation, adjustment, alteration,
service or maintenance can cause injury or
property damage.
Read the instructions thoroughly before installing
or servicing this equipment.
THIS APPLIANCE MUST NOT BE INSTALLED OR
USED INDOORS.
NATURAL GAS APPLIANCE. TO BE INSTALLED
ONLY BY AN AUTHORISED PERSON.
THE AUTHORISED PERSON WILL PROVIDE A
CERTIFICATE OF COMPLIANCE.
A Gasmate NGC30 or NGC40 AGA approved
natural gas pressure regulator must be installed in
the pipeline and be set at 1 kPa.
Conversion ONLY to be done by an authorised person.