Installation
IMPORTANT
Three Phase Units:
Before use, conrm proper rotation of all 3 phase mixers. There is a 50% chance your 3 phase mixer is
properly rotating if you are using it on 3 phase power.
1. Make sure the bowl is empty.
2. Turn the main power switch clockwise to the ON position.
3. Set the speed 2 timer for 30 seconds.
4. Press the SPEED 2 button.
5. Make sure the spiral hook and bowl are going in the direction of the arrow on the bowl as you stand in front
of the mixer (counterclockwise). If the spiral and/or the bowl is traveling in the wrong direction, have a
licensed electrician switch the electrical connection and retest.
10. Complete and register the warranty information online at:
www.globefoodequip.com/support/warranty-registration-form.
11. Mixer must be thoroughly cleaned before use. Refer to Cleaning Instructions section of this manual.
Operating Instructions
TO AVOID SERIOUS PERSONAL INJURY:
DO NOT operate mixer before reading the instruction manual rst.
ALWAYS turn the main power switch OFF before cleaning, servicing, or adjusting parts or attachments.
ALWAYS keep hands, hair and clothing away from moving parts.
Overloading or not following the capacity chart will damage the mixer and void the warranty.
Refer to Capacity Chart section.
Spiral hook must always rotate in a counterclockwise direction around the bowl. If the spiral
hook moves clockwise, contact a licensed electrician immediately to remedy incorrect wiring.
IMPORTANT: When mixing ingredients always make sure to start the mixer on SPEED 1.
1. Raise bowl guard completely until it is in the stored position.
2. Add the appropriate mixing ingredients into the bowl. Add the water rst in order to keep dough from sticking to
bowl and to reduce the risk of airborne our dust.
Slowly add the bag of our or use a scoop to put the our into the
bowl. Adding our slowly reduces the risk of airborne our dust and
injury to operator.
3. Lower the bowl guard until it is in the closed position.
NOTE: Spiral hook will not start if bowl guard is open.
4. Turn the main power switch clockwise to the ON position. See Figure 8-1.
Figure 8-1.