34
Protection
Operating condition
Noise pollution
Install the air conditioner at a place that can bear its weight in order to operate more quietly.
Install the outdoor unit at a place where the air discharged and the operation noise would not annoy
your neighbors.
Do not place any obstacles in front of the air outlet of the outdoor unit lest it increases the noise level.
Features of protector
If all operation has stopped, press ON/OFF button again to restart, Timer should be set again if it has
been canceled.
The protective device will work at following cases.
Restarting the unit at once after operation stops or changing mode during operation, you need to wait for
3 minutes.
Connect to power supply and turn on the unit at once, it may start 20 seconds later.
Features of HEATING mode
Preheat
Defrost
At the beginning of the HEATING operation, the airflow from the indoor unit is discharged 2-5 minutes later.
In HEATING operation the appliance will defrost (de-ice) automatically to raise efficiency.
This procedure usually lasts 2-10 minutes. During defrosting, fans stop operation.
After defrosting completes, it returns to HEATING mode automatically.
Note: Heating is NOT available for cooling only air conditioner models.
1.
2.
Temperature
Cooling operation Heating operation Drying operation
Indoor
temperature
max
32
27
32
min
21
7
18
Outdoor
temperature
max

24 43
min
-15
21
NOTE:
Operating temperature
*Optimum performance will be achieved within these operating temperature. If air conditioner is used outside of
the above conditions, the protective device may trip and stop the appliance.
The temperature of some products is allowed beyond the range. In specific situation, please consult the
merchant. When relative humidity is above 80%, if the air conditioner runs in COOLING or DRY mode with door
or window opened for a long time, dew may drip down from the outlet.
50
-15