46 Part Number: 000015431 Rev 02 6/20
D. Remove the ice thickness probe
Compress the hinge pin on the top of the ice thickness
probe.
Pivot the ice thickness probe to disengage one pin
then the other. The ice thickness probe can be cleaned
at this point without complete removal. If complete
removal is desired, disconnect the ice thickness control
wiring from the control board.
E. Remove the water distribution tube
NOTE: Distribution tube thumbscrews are retained
to prevent loss. Loosen thumbscrews but do not pull
thumbscrews out of distribution tube.
Loosen the two outer screws (do not remove screws
completely they are retained to prevent loss) and pull
forward on the distribution tube to release from slip
joint.
Disassemble distribution tube by loosening the two (2)
middle thumbscrews and dividing the distribution tube
into two pieces.
NOTE: Proceed to step 7 on page 42.