P/N 750301 Page 21
INSTALLATION GUIDE FOR FLUE (PYRAMID STYLE HOOD)
1. MEASURE FROM TOP OF THE CANOPY TO CEILING AND SUBTRACT 1/8" FOR CLEAR-
ANCE.
2. PLACE THE DUCT COVER TOP INSIDE THE DUCT COVER BASE AND LOWER UNTIL DE-
SIRED HEIGHT IS FOUND. (TO ELIMINATE SCRATCHES, MAKE A MARK ON THE DUCT
COVER TOP FOR THE DESIRED LOWERING POINT BY SUBTRACTING 15" FROM THE TO-
TAL HEIGHT NEEDED.)
3. USE THE RETAINING SCREWS TO FASTEN IN PLACE.
4. SLIDE THE DUCT COVER IN PLACE AND FASTEN FROM INSIDE CANOPY USING SHEET
METAL SCREWS.
NOTE: FOR INSTALLATIONS WITH CEILINGS ABOVE 9', USE OPTIONAL CUSTOM FLUES. SEE
PRODUCT LITERATURE FOR DETAILS.
MODEL A DIM B MAXIMUM C” DIM
BS-PC3024 15” 27” 12
BS-PC3624 15” 27” 12
BS-PC4224 15” 27” 15
BS-PC4824 15” 27” 18
BS-PC5424 15” 27” 24
BS-PC6024 15” 27” 24
BS-PC6024 15” 27” 24