THE CORRECT HEIGHT OF YOUR PRO LINE SERIES HOOD
THE BOTTOM OF THE HOOD SHOULD BE 30" MINIMUM TO 36" MAXIMUM ABOVE THE
COUNTERTOP. THIS WOULD TYPICALLY RESULT IN THE BOTTOM OF THE HOOD BEING 66"
TO 72" ABOVE THE FLOOR. THE BOTTOM OF THE HOOD SHOULD NEVER BE MORE THAN
72" ABOVE THE FLOOR OR MORE THAN 36" ABOVE THE COUNTERTOP. THESE DIMENSIONS
PROVIDE FOR SAFE AND EFFICIENT OPERATION OF THE HOOD. IF FOR SOME REASON THE
HOOD IS MOUNTED GREATER THAN 72” FROM THE FLOOR, IT MUST BE 6” WIDER THAN THE
RANGE.
ALL PL MODEL HOODS HAVE THE FLEXIBILITY TO EITHER DUCT FROM THE
TOP OR REAR. CHECK PAGE 13 OF THE MANUAL FOR RECOMMENDED TRANSI-
TIONS. SOME HOODS MIGHT HAVE A 6” ROUND, 10” ROUND OR REQUIRE REC-
TANGULAR TRANSITION. (NOTE: RECTANGULAR TRANSITION INDICATED BE-
LOW TO ILLUSTRATE TOP OR REAR DISCHARGE OPTIONS ONLY.)
TOP DISCHARGE REAR DISCHARGE
HEIGHT FROM FLOOR
68"(MIN)-72"(MAX)
167.6cm-182.9cm
COUNTERTOP
HEIGHT ABOVE COUNTERTOP
30"(MIN)-36"(MAX)
76.2CM-91.4CM