THEAPPLIANCEON,24HOURSISRECOMMENDED.Aftertheunit
hasbeenonitsside,oilneedstoreturntothecompressortoen-
sureproperfunction.Withoutallowingtheunitthistime(6-24
hours)theunitmayfunctionforonlyashorttime,andthenthe
compressorwillbreakdownfromlackofoil.
ELECTRICAL CONNECTION
Thisapplianceisequippedwitha3pronggroundedplug.The
plugmustbeconnectedintoanoutletthatisproperlyinstalled
andgroundedintheaccordancewithalllocalcodesandordi-
nances.Donotmodify theplugprovidedwiththeappliance.
Ifitwillnotttheoutlet,haveaproperoutletinstalledbya
qualiedelectricianorrelocatetheunittoaproperoutlet.Ifthe
householdelectricalsupplydoesnotmeettheabovespecica-
tions,orifyouarenotsureyourhomehasaneectiveelectrical
ground,haveaqualiedelectricianoryourlocalelectricalutility
companycheckitandcorrectanyproblems.
SAFETY PLUG
Theapplianceisttedwithasafetyplugtoprotectthepower
cable.Ifpoweriscuto,unplugfromtheoutletandmakesure
thepowercableisundamaged.Ifthecableisdamaged,callthe
servicecenterimmediately.Ifpowercutsofrequentlyandthe
powercableisundamaged,contactaqualiedelectrician.
OPERATION OF THE SAFETY PLUG
Ifthesafetydeviceincorporatedintheplugtripsandcutso
thepowersupply,checkthatthepowercableandplugarenot
damaged.Ifthepowercableisundamaged,torestoreoperation
pressthe“RESET”button.Toverifycorrectoperationoftheplug,
presstheTEST”buttonperiodicallyandmakesuretheappliance
disconnects.Ifthisisnotthecase,contacttheservicecenter.To
restoreoperation,pressthe“RESETbutton.
TROUBLESHOOTING
CheckthefollowingpointsbeforecallingtheauthorisedTechnicalServiceCentreinyourarea.
PROBLEMS CAUSES SOLUTIONS
Theairconditionerdoesnotturnon ltisnotpluggedin plugitin
thereisnopower wait
theinternalprotectiondevicewastriggere
callthehelpcentre
The air conditioner works for a short
periodoftime
theairexhausthoseisobstructedorbent correctly position the air exhaust hose,
limiting the length and curves as much
aspossibleandavoidinganyobstructions
an obstruction is impeding air exhaust
outside
identify and remove the obstacles that
impedeairexhaustoutside
Theairconditionerrunsbutdoesnotcool
theroom
windows,doors,drapesopen close the windows, doors and drapes,
keeping in mind the “recommendations
forproperuse
there is some heat source in the room
(oven,hairdryer,etc.)
eliminatetheheatsource
theairexhausthoseisdisconnectedfrom
theappliance
attachtheairexhausthosetothehousing
onthebackoftheappliance(g.1)
dustltersclogged clean or replace the lters as previously
described
the technical characteristics of the
appliancearenotsuitableforcoolingthe
roomwhereitislocated
During operation there is an unpleasant
odourintheroom
dustltersclogged clean or replace the lters as previously
described
The air conditioner does not work for
about3minutesfromrestart
to protect the compressor there is an
internal device that delays startup for
about3minutesfromrestart
wait;thistimedelayfromrestartisnormal
Thedisplayshowsthe symbolwith
oneofthefollowingmessages:HL/PF
theappliancehasaself-diagnosissystem
thatidentiessomeoperatingerrors
refertotheSELF-DIAGNOSISchapter