Gas Type
NATURAL
GAS
UNIVERSAL
LPG
Nominal heat input (MJ/h) 52 52
Injector diameter (1/100mm) 170 100
Number of injectors 4 4
Pressure (kPa) 1 2,75
Primary air regulation (mm)
X
2 All open
Adapting to different types of gas
If the appliance is congured for a different type of gas than that available, you have to replace
the injectors with ones corresponding to the type of gas to be used (see tables on the preceding
pages). The replacement will be made using an adequate 7 mm key after having lowered the
burners as in the following images. After replacing the injector, regulate the air to 1mm for natural
gas and to the maximum if LPG.
To adjust the minimum, after lighting the burner, remove the knob and the gasket below and
rotate the screw of the tap (B - see page 70), which should be totally closed for LPG and opened
about 3/4 turn for natural gas, keeping in mind that a ame lower than 3 mm may not even be
perceived by the thermocouple of the tap. After regulating the minimums, replace the gaskets
and knobs.
1 - Unscrew the fixing screws of the burner.