How the Storm SLGR 1600X Works
Guidelines
The Storm SLGR 1600X dehumidier utilizes its integral humidistat to monitor the conditioned
space. Once conditions are outside the desired setpoint, the compresser energizes and air is
drawn across an evaporator coil. The evaporator coil is cooler than the dew point of the air
so the water vapor will turns into liquid condensation. The air is then reheated through the
condenser coil and distributed back into the room.
Operation Notes
Always make sure that the unit is operated, transported, and stored on a stable surface.
For maximum eciency, operate the unit with all windows and doors closed.
Do not place the unit anywhere that may block the inlet or outlet airow.
Drain Hose Notes
The Storm SLGR 1600X is equipped with an external drain line connection, making it easy to plug in.
The drain line can be directed outside or into any sink, drain, etc.
For more eective draining, uncoil the entire hose before using.
Never place the end of the hose higher than 15 feet.
Always ensure that the drain hose is not blocked prior to use.
Transportation Notes
Always secure the dehumidier during transportation
If the unit is transported vertically, return it to a normal horizontal position, and let sit for 30
minutes prior to use.