Mr. Heater F236120

User Manual - Page 3

For F236120.

PDF File Manual, 24 pages, Read Online | Download pdf file

Loading ...
Loading ...
Operating Instructions and Owner’s Manual
3
Mr. Heater Forced-Air Electric Construction Heater
5.Turnthermostatknobup(clockwise)tothedesiredsetting.
6.TheHeatingelementandfanwillremainonuntilthetemperature
settingisreached.Theunitwillcycleonandoffasneeded.
To Stop Heating
1.Rotatethethermostatknobtothelowestposition.
2.Flipthepowerswitchintothe“off”position.
3.Disconnectplugfrompowersupply.
NOTE:Thisheaterisequippedwithanoverheatlimitswitch
whichmaycausetheheatertostop.Thisisindicatedbyavisual
alarmwhenthepowerswitchisinthe“ON”positionandthe
“fault”lightcomeson.Checkandremovethecauseofthe
overheatingbeforerestarting.Thiscantakeupto10minuetsto
coolbeforeitcanberestarted.
Maintenance
WARNING:
Neverattempttoservicetheheaterwhiletheunitishot,
Inuse,orpluggedin.Onlyqualifiedservicetechnicians
shouldservicetheseunits.
•Thoroughlyinspecttheunitpriortouse.
•Keepheatercleanandfreeofdustanddebris.
•Theuseofanaircompressorcanbeusedtoblowoutthedust
fromtheheatercase.
Besuretoonlyusemoderateairpressure
astonotdamageanyinternalcomponents.
•Asoftdryclothshouldbeusedforcleaningofoutershell
andhandle.
•Thefanmotorissealedanddoesnotneedtobelubricated.
Storage
Whennotinuse,theheatermustbedisconnectedfrompower
source,dustedoffandthecordshouldbelooselywound
aroundthehandle.
For service :
PleasecallToll-Free800-251-0001www.mrheater.com
Ourofficehoursare8:00AM–5:00PM,EST,Mondaythrough
Friday.Pleaseincludethemodelnumber,dateofpurchase,and
descriptionofprobleminallcommunication.
MH165FAET
NEMA5-15R
MH360FAET
NEMA6-20R
SPECIFICATIONS
Model: MH165FAET MH360FAET
HeatOutputBTU/WATTS 5118/1500
12286/3600
Airflow(CFM) 200 325
ElectricalSupply 120Vac 240Vac
Thermostat 32°F-185°F 32°F-185°F
PowerCord
6’POWERCABLEINCLUDED 6’POWERCABLEINCLUDED
Dimensions:(L”xW”xH”) 13.18”x12.2”x13.97” 14.37”x13.77”x16.14”
Weight(lbs.) 9.6LBS. 12LBS.
Clearance to Combustibles
Outlet(M) 6’(1.8M) 6’(1.8M)
Rear(M) 2’(.6M) 2’(.6M)
Top(M) 2’(.6M) 2’(.6M)
Bottom(M) Useonlyonnon-combustibleflooring
Assembly
• Removetheheaterandallofthepackagingmaterialfrom
thebox.
• Checkallofthepackingmaterialforloosepartsandset
aside.
• Thoroughlyinspecttheheaterfordamage.Ifanyisfound
donotcontacttheplaceofpurchase.Pleasecallthe
Manufacturerat800-251-0001.
Operational Information
TheMr.HeaterElectricforcedairheatersaredesignedtobe
usedbyprofessionals.
Heatiscreatedbyelectriccurrentpassingthroughcoiledmetal
elementsbringingthemuptoveryhightemperatures.Thefanthen
passesroomairoverthehotelementsexchangingcoldairforwarm.
Theairmovingoverthecoilskeepsthemfromreaching
temperaturesthatarenotsafeforthenormaloperationof
theheater.Howeveritisimportanttokeepallcombustible
materialsandanyobjectsthatmaybesuckedintothefan
bladesatasafedistance(pleaserefertothespecificationtable
forappropriateclearances).Makesurethatthefanblades
remainunobstructedatalltimes.Keepunitcleananddustfree.
Donotblockunitintakeorexhaustatanytime.
Theseunitsaredesignedtobeusedonlywiththecordand
plug suppliedwiththeunit.Donotuseanyplugotherthanthe
onesuppliedbythemanufacturer.Forinformationonwhich
receptacleisappropriate,RefertoFigure1andfindthediagram
thatcorrespondstoyourheater.
Ifdamagehasoccurredpleaserefertothepartslistinginthis
manualandcontactthemanufacturerforareplacement.
WARNING:Outletmustbeproperlygrounded,failuretodo
somayresultinelectricshockorpropertydamage.
WARNING: Alwaysplugheatersdirectlyintoawalloutlet/
receptacle.Neverusewithanextensioncordorre-locatable
powertap(outlet/powerstrip).
Starting Instructions
1.Placetheheateronastableandlevelsurface.Insureclearanceto
combustiblesareobserved(Seeclearancesinthespecificationtable).
2.Turnthermostatcounter-clockwisetolowestsetting.
3.Plugtheheaterintoaproperlygroundedoutlet.
4Rotatethepowerknobtotheheatingposition.Theseunitsare
equippedwithafanonlyoptionforcirculatingair.Forheatingbe
suretorotatetheknobtotheappropriatesetting.
Figure1
CONTROL
OFF
FAN
ONLY
HEAT
THERMOSTAT KNOB
OVERHEAT LIGHT
Loading ...
Loading ...