All equipment and systems used to deliver water to the
appliance must comply with local code.
The Combi Steam Oven may only be connected to the cold
water line.
An extra non-return valve is not required.
The water intake pressure must be at least 14.5 psi (1 bar)
and may not exceed 87.02 psi (6 bar). If the pressure is
higher than 87.02 psi (6 bar), a pressure reducing valve must
be installed.
The water intake hose must be connected to the drinking
water supply by a water faucet with a 3/4" threaded union. If
this is not present one must be installed by a licensed
plumber.
The stainless steel water intake hose supplied must not be
shortened.
If required, water inlet tubing with a length of 118" (3,000 mm)
is available. The tubing must not be shortened either.
Old or previously used hoses must not be connected to
the appliance.
The entire hose length must not exceed 24' 7" (7.5 m).
Before connecting the appliance, and after any work on the
water supply, the water line must be flushed to remove
debris.
Water connection
155