Fault Cause Troubleshooting
Appliance door does not
open at the end of the Eco
50° programme.
The safety device will switch
Eco drying off.
Call "Customer Service."
→Page58
Appliance door automatic-
ally opens too wide at the
end of the Eco 50° pro-
gramme.
Door is not correctly adjus-
ted.
Adjust the appliance door as de-
scribed in the installation instruc-
tions.
The door gap must be at least
70mm - 100mm.
Wrong screws used to ad-
just the door gap.
Use size 4X30 screws to adjust the
door gap.
The screws are included in the
scope of supply.
If the screws used here are too
long, this may deactivate Eco dry-
ing.
Appliance door does not
open.
Door is not correctly adjus-
ted.
Adjust the appliance door as de-
scribed in the installation instruc-
tions.
Appliance has no power.
Check the mains plug and fuses.
1. Position the emergency release
supplied on the top right and left of
the cabinet panel.
2. Open the appliance door by pulling
lightly.
Appliance door and door
seal are soiled.
Clean the appliance door and door
seal with a damp cloth and a little
washing-up liquid.
Automatic door opening is
not in home position.
Wait one second after closing the
appliance door.
Appliance door opens too
wide when activated.
Door is not correctly adjus-
ted.
Adjust the appliance door as de-
scribed in the installation instruc-
tions.