CHARGING PHASES
BulkSoft StartDesulphation Absorption Analysis PulseFloatRecond
CurrentVoltage
Mode chosen: ”NORMAL” or ”SNOWFLAKE”
MULTIUS7002isamultistagefullyautomaticcharger.LampBforchosensetting
´1250$/´DQGODPS&IRUFKRVHQVHWWLQJ´612:)/$.
Desulphation (Lamp 1, blinking)
Desulphation with pulsing for sulphated batteries. Indicated by blinking lamp 1.
Start (Lamp 1)
Starting phase for charging. The starting phase continues until the battery’s terminal volt-
age has risen over a preset level. At this point, charging goes into the bulk phase. If the
terminal voltage has not reached the preset level within 8 hours, charging is suspended.
The error mode is indicated. This indicates a battery which is faulty or has too large
capacity.Ifalargebatteryischargedthathasbeenseverelydischarged,itmaybeneces-
sarytorestartthechargerafter8hours.Startisindicatedbylamp1.
Bulk (Lamp 2)
Primary charging where approximately 80% of the charging happens. The charger
deliversmaximumvoltageuntiltheterminalvoltagehasrisentothepresetlevel.Aftera
numberofhours,thechargergoesontothenextphase,evenifmaximumvoltageisnot
reached. Bulk is indicated by lamp 2.