Error mode
The charger enters error mode before start in the following situations:
The battery is connected with poles reversed to the charger's terminals.
The terminals on the charger are short-circuited.
Error mode before start is reset by removing the error situation. The charger restarts in
thelatestselectedmode.
Thechargerenterssteadyerrormodeinthefollowingsituations:
The charger’s analysis function has interrupted charging.
ThechargerisoverloadedinSupplymode.
The charger has been in start mode longer than maximum time.
6WHDG\HUURUPRGHLVDFNQRZOHGJHGUHVHWE\SUHVVLQJWKH´02'(´EXWWRQ7KHFKDUJHU
restarts in the latest selected mode.
BULK CHARGING TIME
Battery size (Ah) Time to ~80% charge (h)
14 2
50 6–7
90 11–13
150 20–22
•
•
•
•
•