- 7 - - 8 -
DC Current
Range Resolution
Accuracy
Overload
Protection
200µA 0.1µA
315mA,
250V fast
type fuse:
5x20mm
2000µA 1µA
- - - - - -
± (1%+2)
20mA
10µA
200mA
100µA ± (1.2%+2)
10A 10mA
± (2%+5)
Un-Fused
At 10A Range: for continuous measurement 10 seconds
and interval not less than 15 minutes
Resistance
Range Resolution Accuracy
Overload
Protection
200Ω 0.1Ω ± (0.8%+5)
250V DC
or AC
2000Ω 1Ω
± (0.8%+2)20KΩ 10Ω
200KΩ 100Ω
20MΩ 10KΩ ± (1%+5)
200MΩ 100KΩ
±
[5%(reading
-
10)+10]
Diodes and Continuity Measurement
Range Resolution Remark
Overload
Protection
1mV
Display
approximate
forward voltage
drop: 0.5v ~ 0.8v
250V DC or AC
1Ω
Buzzer beeps
at < 70W
Square Wave Output
Range Illustration
OUT
Approx. output 50Hz square wave signal.
As a simple signal source with 47KΩ
resistance output.
No overload protection
Make sure voltage output of calibrated equipment level is
less than 10V to avoid damages to the meter