INSTALLATION07
Changing direction of the drain hose
• Thehosewillbexedpermanentlyintopositionafternishingtheinstallationandthegasleaktest;
refer to page 52 for further details.
• Makesuretheinstalleddirectionofthedrainhoseiscorrect.
Inadequate installation may cause condensate water leakage.
• Ifthedrainhoseisroutedinsidetheroom,insulatethehosesothatdrippingcondensationdoesnotdamagethe
furniture or oors.
• DONOTWALLUPTHEDRAINHOSECONNECTION!
Drain hose connection must be easy accessible and serviceable.
6. Pass the drain hose under the refrigerant pipe, keeping the drain hose tight.
7. Pass the drain hose through the hole in the wall. Check if it slants
downwards as seen in the picture.
8. Using natural drainage method, check the drainage is normal.
Shield
Drain hose Extension drain hose
Drain hose
Extension
drain hose
Drain hose
Extension
drain hose
40~45 mm
Foam Insulation
20 mm
or more
20 mm
or more
Vinyl Tape
• Makesuretheindoorunitisinuprightpositionwhenyoupourwatertocheckforleakage.
Make sure that the water does not overow onto the electrical part.
Change the direction only when it is necessary.
1. Detach the rubber cap with the plier.
2. Detach the drain hose by pulling it and turning to the right.
3. Insert the drain hose by xing it with the screw into the groove of the drain
hose and the outlet of the drain pan.
4. Attach the rubber cap with a screwdriver by turning it to the left until it xes
to the end of the groove.
5. Check for leakage on both side of the drain outlet.
Drain hose
Screw hole
Screw
Rubber cap
Drain pan outlet
Pour the water in direction of arrow.