Garland MPGS20S MP-GS-20-S 38" Moisture+ Full-Size Convection Double Oven with 160000 BTU Total Power, Solid State Controller, Two Speed Fan with 3/4 HP Fan Motor and Quartz Illumination in

User Manual - Page 25

For MPGS20S.

PDF File Manual, 80 pages, Download pdf file

Loading ...
Loading ...
Loading ...
Part # MPSM07 (03/24/08) Page 25
Display Messages
The display will be blank if the oven has been O longer than 30
seconds.
This is the message that is displayed when the On/O key is pushed
and the unit is powering down. This message is displayed for 30
seconds before going blank. It is also displayed when the Auto Cool
Down function shuts o.
This is a warning message shown when the oven cavity temperature
exceeds the programmed temperature by more than 25ºF. The actual
temperature and programmed temperature are also displayed.
This is the warning message shown when the oven cavity
temperature exceeds 575ºF. All oven function is shut down and the
user must remove power from the oven to reset the control after
correcting the error. The audible alarm will sound continuously.
If the control senses that the cavity probe shorts out or goes to an
open circuit this message will be displayed and the audible alarm will
sound continuously.
Repeat steps 4 through 7 for each individual shelf
position/shelf timer key that will be used.
9. After programming all the shelf timers that will be used,
press the Program key. This will return the oven to idle
mode.
Cooking with shelf timers:
1. Press the numeric key corresponding to the desired
prole, (fan setting, temperature and time; see To
program shelf timers:’ on the previous page). Allow the
oven to heat to the programmed temperature. When the
programmed temperature has been reached, the display
will indicate READY.
2. Load product on the desired shelf, close the door, and
press the same key that was pressed in Step 1. The display
will indicate ENTER SHELF.
Press the numeric key, (1 - 6), corresponding to the shelf
loaded. Press the Start/Cancel key to engage the timer
countdown for the selected shelf.
3. Repeat Step 2 up to ve times while loading the remaining
shelves.
Note: The display will show only one timer countdown at a
time. The shortest, (time remaining), of all the active shelf
timers will be displayed.
4. When the shortest of the active shelf timers has expired,
the display will indicate DONE SHELF X, where X equals
the number of the shelf timer that has expired, and an
audible alarm will sound continuously for 10 seconds. The
LED on the expired timers key will ash. Press that timer
key to cancel the alarm, unload the nished product from
the corresponding shelf immediately and close the door.
The timer display will change to show the countdown of
the shortest of the remaining active shelf timers. Repeat
this step until all of the active timers have expired and
their respective shelves are unloaded.
If the alarm is not canceled after sounding continuously
for 10 seconds, it will sound a short tone once every 15
seconds until the corresponding shelf timer key is pressed.
The display will continue to indicate SHELF X and the
timer keys LED will continue to ash.
If an alarm isn’t cancelled before the next timer expires,
the alarm will sound continuously and both keys LED’s
will ash. The display will continue to show the rst
expired shelf timer number indicating the rst shelf to
be unloaded. Cancel the displayed timer by pressing the
corresponding shelf timer key once, then unload the shelf.
The display will indicate Shelf X, where X is the number of
the next shelf to be unloaded. Expired, uncanceled shelf
timers will continue to be displayed in the order of their
expiration as each previous timer is cancelled.
Loading ...
Loading ...
Loading ...