SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
CasétaR Wireless Load Controls
369987a 12 09.09.16
Wiring Diagrams - Switches (cont.)
3-Way Installation (with mechanical switch)
Option 1 (cont.)
Location 2
Location 2
PD-6ANS
1
Mechanical
Switch
1
Brass
Brass
Load
Line/Hot
Neutral
GreenWhite
Ground
Ground
Black Red
3
Blue
120 V~ 50/60 Hz
Black
Jumper
wire
PD-6ANS (Load-side)
Ground
GreenWhite
Line/Hot
Neutral
120 V~
50/60 Hz
Black
Red
3
Blue
Brass
Jumper wire
Black
Brass
Load
PD-6ANS
1
PD-6ANS (Line-side)
Mechanical
Switch
1
Ground
Location 1
Location 1
1
Location of Caséta® Wireless In-Wall Switch and mechanical switch may be reversed.
2
A LUT-MLC ensures proper function when LED, fluorescent, or ELV loads are used. Install the LUT-MLC inside a load fixture or in a separate junction box within the circuit.
3
The red wire must be connected to the load and the black wire must be connected to Line/Hot. The switch will not work if the wires are reversed.
12