Planning
Electrical Outlet Location
Flex Blower only
CAUTION
All electrical wiring should be done by a qualifi ed
person(s) in accordance with all applicable codes
and standards.
This downdraft blower using the Flex Blower (purchase
separately) draws 3.0 Amps and requires a
120 VAC, 60 Hz circuit.
The unit has a 30 in. long power cord with a 3-pronged plug.
Plan to provide a grounded outlet in a location which will
allow the unit’s power cord to reach.
Install electrical box according to local codes.
Note: The unit electrical panel can be installed in remote
location (as show below) to help reach the outlet (see page 16).
CAUTION
All electrical wiring should be done by a qualifi ed
person(s) in accordance with all applicable codes
and standards.
If using a remote blower (purchase separately), the
system draws 6.0 Amps (max.) and requires a 120 VAC,
60 Hz circuit.
The unit has a 30 in. long power cord with a 3-pronged plug.
Plan to provide a grounded outlet in a location which will allow
the unit’s power cord to reach.
Install electrical box according to local codes.
Note: The unit electrical panel can be installed in remote
location (as shown below) to help reach the outlet (see page 16).
Exterior or In-Line Blower only
Mount a standard wiring box, with 3-pronged receptacle, within reach
of downdraft’s power cord. Run appropriate power cable and connect it
to receptacle.
Mount a standard wiring box, with 3-pronged receptacle, within reach
of downdraft’s power cord. Run appropriate power cable and connect it
to receptacle.