Zephyr AK9352BS Monsoon II 54" Stainless Steel Hood Insert

User Manual - Page 32

For AK9352BS.

PDF File Manual, 72 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
32
Monsoon II Use, Care, and Installation Guide
MONSOON II
INSERT
PRO
Troubleshooting
The hood is not venting
out properly.
Using the wrong size of ducting. Change the ducting to the correct size
The hood might be hanging to high
from the cook top.
Adjust the distance between the cook top
and the bottom of the hood within 24” and
36” range.
The wind from the opened windows
or opened doors in the surrounding
area are aecting the ventilation of
the hood.
Close all the windows and doors to eliminate
the outside wind flow.
Blockage in the duct opening or
ductwork.
Remove all the blocking from the duct work
or duct opening.
The unit turns on by
itself.
A spot light is shining directly onto
the switch controls.
The switch controls are light sensitive. A
direct light source onto the switch controls
may disrupt switch functions.
Filter is vibrating Filter is loose. Adjust or change the filter.
Spring clip is broken on the filter. Change the spring clip.
RF Remote control does
not work.
Battery is dead. Replace battery with type A23 12v.
Poor communication with the liner. Remote control must be within 15 ft of liner.
RF Remote lost communication with
the liner.
Reset liner and remote by switching power
o at the circuit breaker for 5 minutes.
Place remote on counter top near the liner
and switch the circuit breaker back on.
Possible Problem Possible Cause Solutions
Loading ...
Loading ...
Loading ...