Zephyr AK9352BS Monsoon II 54" Stainless Steel Hood Insert

User Manual - Page 31

For AK9352BS.

PDF File Manual, 72 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
31
Monsoon II Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Troubleshooting
Possible Problem Possible Cause Solutions
After installation, the
unit doesnt work.
The power source is not turned ON. Make sure the circuit breaker and the unit’s
power is ON.
The power line and the cable
locking connector is not connecting
properly.
Check the power connection with the unit is
connected properly.
The switch board or control board
wirings are disconnected.
Make sure the wirings at the switch board
and control board are connected properly.
The switch board or control board is
defective.
Change the switch board or control board.
The wires on control board are loose. Make sure the wires on the control board
are connected properly.
Light works, but blower
is not turning.
The blower wire is not connected. Make sure the blower wire is plugged into
the molex connector.
The thermally protected system
detects if the blower is too hot to
operate and shuts the blower down.
The blower will function properly after the
thermally protected system cool down.
Damaged capacitor. Change the capacitor.
Blower molex plug pin is not making
contact.
Disconnect the blower molex plug, check
pins inside plug to see if pin is pushed inside
the plug too far. Reset pin if needed.
The blower is defective, possibly
seized.
Change the blower.
The unit is vibrating. The blower is not secured in place. Tighten the blower in place.
Damaged blower wheel. Replace the blower.
The hood is not secured in place. Check the installation of the hood.
The unit is whistling. A filter is not in the correct position. Adjust the filters until the whistling stops.
The duct pipe connections are not
sealed or connected properly.
Check the duct pipe connections to be sure
all connections are sealed properly.
The blower is working,
but the lights are not.
The LED light connector is
disconnected.
Connect the LED light connector.
Defective LED light. Change the LED light.
The switch board or control board is
defective.
Change the switch board or control board.
Loading ...
Loading ...
Loading ...